Actions

IP Flush Master and IP Flush Handset compatibility

From Zenitel Wiki

Revision as of 11:39, 10 April 2013 by Roarl (talk) (Created page with "The latest version of the IP Flush Master (revision 1008031.0400 or newer) is compatible with new IP Flush Handset (revision 1008071000.0300 or newer). It is unfortunately not co...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

The latest version of the IP Flush Master (revision 1008031.0400 or newer) is compatible with new IP Flush Handset (revision 1008071000.0300 or newer). It is unfortunately not compatible with older IP Flush Handset.

The previous version of IP Flush Master (revision 1008031.0301 and older), is compatible with older IP Flush Handset (revision 1008071000.0201 and older). It can also use new IP Flush Handset (revision 008071000.0300 or newer) through a workaround described below).

NOTE: This requires a SW update to version 02.03.3.1 or newer.
COMPABILITY TABLE New handset (from rev 0300) Older handset (up to rev 0201)
New station (from rev 0400) YES Modification required
Old station (up to rev 0301) Workaround YES


Description of workaround:

  • Connect the IP Handset to the HEADSET-input of the station
  • A web-configuration “Handset in Headset Slot”, found under “Audio”, must be activated to configure this input to be a handset input (available from SW version 02.03.3.1 and onwards).


IPFlushComp1.PNG


NOTE: This workaround is only applicable in AlphaCom-mode.

Description of modification:

  • Connect the IP Handset to the HEADSET-input of the station
  • A web-configuration “Handset in Headset Slot”, found under “Audio”, must be activated to configure this input to be a handset input (available from SW version 02.03.3.1 and onwards).
  • Dismantle the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image below:


IPFlushComp2.png