IP Flush Master and IP Flush Handset compatibility

From Zenitel Wiki

Revision as of 15:23, 3 May 2013 by Asle (talk)

The latest version of the IP Flush Master (revision 1008031.0400 or newer) is compatible with new IP Flush Handset (revision 1008071000.0300 or newer). It is unfortunately not compatible with older IP Flush Handset.

The previous version of IP Flush Master (revision 1008031.0301 and older), is compatible with older IP Flush Handset (revision 1008071000.0201 and older). It can also use new IP Flush Handset (revision 008071000.0300 or newer) through a workaround described below).

NOTE: This requires a SW update to version 02.03.3.1 or newer.
COMPABILITY TABLE New handset (from rev 0300) Older handset (up to rev 0201)
New station (from rev 0400) YES Modification required
Old station (up to rev 0301) Workaround YES


Description of workaround:

  • Connect the IP Handset to the HEADSET-input of the station
  • A web-configuration “Handset in Headset Slot”, found under “Audio”, must be activated to configure this input to be a handset input (available from SW version 02.03.3.1 and onwards).


IPFlushComp1.PNG


NOTE: This workaround is only applicable in AlphaCom-mode.

Description of modification:

  • Connect the IP Handset to the HEADSET-input of the station
  • A web-configuration “Handset in Headset Slot”, found under “Audio”, must be activated to configure this input to be a handset input (available from SW version 02.03.3.1 and onwards).
  • Dismantle the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image below:


IPFlushComp2.png



New text:


There are two main hardware revisions of the Handset 1008071000 for IP Flush Master stations. Compatibility with the IP Flush Master station is as follows:

Handset revision 1008071000.0300 or newer (from May 2013)

In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
  • Used with IP Flush Master revision 1008031000.0400 or newer: The handset is directly compatible with the IP Flush Master. Connect the handset to the handset connector of the station.
  • Used with IP Flush Master revision 1008031000.0301 or older:
    • Update the software of the IP Flush Master to version 02.3.3.1 or later
    • Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
    • Connect the Handset to the HEADSET-connector of the station

Handset revision 1008071000.0201 or older

Upgrade the handset to version 0300 by adding a strap
  • The handset is directly compatible with IP Flush Master revision 1008031000.0301 or older. Connect the handset to the handset connector of the station.
  • On IP Flush Master revision 1008031000.0400 or newer:
    • Upgrade the handset to revision 0300 by dismantling the handset by unscrewing the two screws, flip the circuit board over and solder a strap as shown in the image.
    • Connect the handset to the handset connector of the station.

About noise in the ear-piece of the handset

When handset revision 1008071000.0201 or older is used with IP Flush Master revision 1008031000.0301 or older, one might experience noise in the ear-piece of the handset. This can be improved by upgrading the handset to revision 1008071000.0300, and use the headset input of the station.

Procedure:

  • Dismantle the handset by unscrewing the two screws
  • Flip the circuit board over and solder a strap as shown in the image
  • Update the software of the IP Flush Master to version 02.3.3.1 or later
  • Log on to the StationWeb. In Advanced Configuration -> Audio, enable the flag “Handset in Headset Slot”
  • Connect the Handset to the HEADSET-connector of the station


NOTE: The option to use the headset input also for handset is a workaround only available in AlphaCom-mode.