Actions

TFIX Restore Factory Defaults

From Zenitel Wiki

Revision as of 14:04, 2 February 2017 by Asle (talk)

A Turbine EX Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.

NOTE! A TFIX Factory Default will also reset the Flowire NMK password. See here for more

Reset to Factory Default Settings with Activated DHCP

Factory Default with IP address from DHCP server

To reset:

1. While pressing any button, power up the station.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 5 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button to make the station say its IP address.

Factory default values

Station IP address: (determined by DHCP server)
Username: admin
Password: alphaadmin


Reset to Factory Default Settings with Static IP

Factory Default with Static IP Address

To reset:

1. While pressing any button, power up the station.
2. Hold the button until the station audio starts counting, and release the button on count 1.
3. Press and hold the button on count 3 and release on count 0.
- if there is no 0 count, the procedure has failed and you have to start again
4. Press the call button to make the station say its IP address.

Factory default values

Station IP address: 169.254.1.100
Username: admin
Password: alphaadmin