Actions

IP Heavy Duty Connections

From Zenitel Wiki

Revision as of 09:17, 25 October 2016 by Roarl (talk) (Introduction)

Introduction

The table below is an overview of the main connectors involved when installing the STENTOFON IP Heavy Duty stations.

Note! To access these connectors the frontplate must be removed
LAN 10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX 10/100 Mbps RJ-45 ports for auxiliary equipment such as PC and IP camera.
Input/Output Pluggable screw terminal
Local Power Plugable screw terminal, 19-27 VDC Idle 4W, max. 8W

Power Supply

The IP Heavy Duty Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Substation can be connected to a 24 VDC local power supply.

Network Connection

There are two RJ45 ports on the IP Stations (except IP Dual Display):

  • LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
  • AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
IP Substation


Input/Output Connections

There are I/O connection options for all IP Substations. These I/O connections include:

  • 3 digital inputs (P4)
  • 1 logical output (TP9)
  • 1 relay output (P3)

These connections are used as relay contacts for door lock control and external I/O devices.

For pin settings on the P3 and P4 connectors on the station board, see See Related Article IP Station Board Connections and Indications.