The table below is an overview of the main connectors involved when installing the IP Hotline Station.

LAN (P1) 10/100 Mbps RJ45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX (P2) 10/100 Mbps RJ45 port for auxilliary equipment such as PC or IP Camera.
Input/Output Pluggable screw terminal
Local Power Pluggable screw terminal, 17-27 VDC Idle 4W, max. 8W

To access these connectors the front cover must be removed.

Power Supply

The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Hotline Station can be connected to a 24 VDC local power supply.

See Related Article INCA Master Station Kit Board Connectors for local power supply connections.