Actions

IP-ARIO Restore Factory Defaults

From Zenitel Wiki

Revision as of 11:14, 26 October 2016 by Roarl (talk)
Front view

To configure the IP-ARIO unit with Factory Default IP Settings do the following:

  1. Disconnect power to the unit.
  2. Reconnect power and within 5 seconds, use a pin to press and hold the pinhole Reset button (on the front right of the unit).
  3. Keep the Reset button pressed until the CALL LED emits 3 slow flashes followed by 3 fast flashes as confirmation that the unit is reset. (Takes appr. 25 seconds)
  4. Release the Reset button.

The unit’s IP settings will now be reset to factory default.

Factory default values
Station Mode AlphaCom
Station IP address 169.254.1.100
AlphaCom IP address 169.254.1.5
Username* admin
Password* alphaadmin
* Software 01.06 and earlier: ADMIN/alphacom)