Actions

IP Heavy Duty - Restore Factory Defaults

From Zenitel Wiki

Revision as of 13:12, 17 March 2017 by Asle (talk)
APS.png
The IP Heavy Duty Stations

This procedure is applicable for the IP Heavy Duty station 1008072xx0

  • The Factory Default can be either set to Static IP address 169.254.1.100 or one can activate DHCP.
  • Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
Load Defaults without KEY.PNG


Restore with Static IP

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 2 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 2 times indicating a successful reset with static IP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100
  • Username: admin
  • Password: alphaadmin

Restore with Activated DHCP

The DHCP option is available from software version 01.07.

  1. While pressing the button, power up the station kit.
  2. When the station kit LED starts blinking, release the button after exactly 2 blinks.
  3. Let the LED blink for exactly 4 more times, then press the button again.
  4. Keep the button pressed until the LED blinks fast 4 times indicating a successful reset with activated DHCP.
  5. Release the button and the station kit will restart with the factory default settings.

Factory default values:

  • Station Mode: Pulse
  • Station IP address: From DHCP server
  • Username: admin
  • Password: alphaadmin