Delayed Reporting of Line Errors
From Zenitel Wiki
By default station errors are reported more or less instantly when the AlphaCom server looses connection to an IP Station, or if there is an error on the analog ASLT station line.
Sometimes it could be convenient to delay the reporting, for example if there is maintenance work in the IP network, repatching of cables etc.
This article describes how to disable the default reporting, and how to use customized error reporting using the Event Handler instead.
Disable default Line Error reporting
Reporting to station
Station errors are by default sent to station on physical number 1. From AlphaPro one can disable this reporting.
Go to the Exchange & System > RCI > Faults window, select Fault Line > Change, and delete the MST command in the ON Action field.
Disable reporting to System Log
Station errors are by default sent to the System Log. From AlphaPro one can disable this reporting.