TCIS Restore Factory Defaults
From Zenitel Wiki
A Turbine IP Station may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
Reset to Factory Default Settings with DHCP
To reset:
- Press and hold any button, then power up the station.
- At the count 1, release the button
- At the count 5 press and hold the button.
- At the count 0 release the button. If there is no 0 count, the procedure has failed and you have to start again
After the station has started up, press the call button, and the station will speak its IP address
Factory default values
- Station IP address: Obtained from a DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
- Username: admin
- Password: alphaadmin
- Mode of operation: Edge
Reset to Factory Default Settings with Static IP
To reset:
- 1. While pressing any button, power up the station by connecting to a PoE switch.
- 2. Hold the button until the station audio starts counting, and release the button on count 1.
- 3. Press and hold the button on count 3 and release on count 0.
- - if there is no 0 count, the procedure has failed and you have to start again
- 4. Press the call button, and the station will speak its IP address.
Factory default values
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin
- Mode of operation: Edge