This articles shows possible solutions for redundancy with the ICX-AlphaCom server.

Power Supply

The ICX-AlphaCom normally has one power supply, and it only supports one power input. Using third party products it is possible to Increase durability by adding a solution for redundant power.

Redundan Power Supply solution using Phoenix Contact products


The optional TKIS-2 is used in case it is a full redundancy system, with redundant ICX-AlphaCom servers.

The TKIS-2 will then always be registered and can be used to monitor the power supplies as well as the ICX-AlphaCom. Such a full redundant system might look like this:

Principal sketch for redundancy system


Serial Port

The ICX-AlphaCom does not have a serial port and must use an Ethernet-to-serial converter. Since the ICX-AlphaCom redundancy system is using a singular IP address as the operational IP address the solution is to have the converter pointed at the operational IP address, and will work fine, independent on which server is the active one.