Kits - Comparison chart
From Zenitel Wiki
Revision as of 13:23, 24 October 2023 by Lennert.werf (talk | contribs)
Zenitel offers a number of IP based kits, which can be used for a wide range of applications.
This article compares the properties and capabilities of the different kits, and indicates which kit is best fit for a certain application.
Kit offerings
ZMK-1 | TKIS-2 | TKIE-1 | TKIE-2 | TKIE-3CC | IP-LCM | TKIV+ |
Properties and capabilities
Kit | General | Audio out | Audio In | I/Os | Accessories | Support for: | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Item no. | Housing | Ethernet ports | Loudspeaker output | Line Out (0 dBm) | Additional speaker | Microphone | Line In | Relays | Digital I/Os | Inputs as key matrix | Handset | Headset | Keyboard | LCD Display | HDMI (touch)Display | DAK48 module | Camera | USB-C HID |
TKIS-2 | 1008131020 | Plastic | 1 | 10W | Yes | No | Electret mic | No | 1 | 6 | Yes *** | No | No | No | No | No | No | No | No |
TKIE-1 | 1008132010 | No | 2 | 10W | Yes | No | Electret mic | Yes | 2 * | 6 | Yes *** | Yes | Yes | No | No | No | No | No | No |
TKIE-2 | 1008132020 | Metal | 2 | 10W | Yes | No | Electret mic | Yes | 2 * | 6 | Yes *** | Yes | Yes | No | No | No | No | No | No |
TKIE-3CC | 1008132030 | No | 2 | 10W | Yes | No | Electret mic | Yes | 2 * | 6 | Yes *** | Yes | Yes | Yes | No | No | No | No | No |
IP-LCM | 1008095201 | Plastic | 1 | 10W | Yes | No | Electret mic | No | 8 + 1 | 8 + 6 | Yes *** | No | No | No | No | No | No | No | No |
TKIV+ | 1008331010 | Plastic | 1 | 10W | Yes | No | Electret mic | No | 1 | 6 | Yes *** | No | No | No | No | No | No | Yes | No |
IPMSK-V2 | 1008493000 | No | 2 | 1.5W | No | 5 W | Electret mic | No | 1 | 3 inputs | No | Yes | Yes | Yes | Yes | No | Yes | No | No |
ZMK-1 | 1008493000 | Metal | 2 | 15W | Yes | No | Electret mic | Yes | 1 | 2 inputs | Yes | Yes (USB-C) | Yes (USB-C) | Yes (USB-C) | No | Yes | No | Yes (USB-C) | Yes |
- * Two more relays (4 in total) by using the TA-10 module in combination with the TKIE kit.
- ** LCD Display for Master kit: 1008099000
- *** Four inputs can be combined in a matrix function, providing 15 different input signals. This is supported in SIP mode and Edge mode only.
Relay switching capacity:
- TKIS and TKIE: 60 watt (max. 250VAC)
- IP-LCM and TA-10: 8A (max. 250VAC)
Application areas
The table below shows which kit is best fit for a certain application. Please note that often several types of kits might be suitable for the same application.
Category | Application | TKIS-2 | TKIE-1 | TKIE-2 | TKIE-3CC | IP-LCM | TKIV+ | IPMSK-V2 | ZMK-1 |
Substation | Up to 6 call buttons *** | ||||||||
Substation | Up to 6 call buttons, camera | ||||||||
Substation | Up to 6 call buttons, handset | ||||||||
Substation | Up to 6 call buttons, headset | ||||||||
Substation | (Touch)Display, camera | ||||||||
Masterstation | with full keypad | ||||||||
Masterstation | with full keypad and LCD display | ||||||||
Masterstation | with full keypad, LCD display and support for DAK-48 module | ||||||||
Audio Interface | PA (Public Address) amplifer | ||||||||
Audio Interface | Mobile Radio system (ICX-AlphaCom) | ||||||||
Audio Interface | Program Source (ICX-AlphaCom) | ||||||||
Audio Interface | Customized IP Speaker | ||||||||
Audio Interface | Customized IP Speaker, answer in speaker | ||||||||
I/O device | Input device for receving alarms (dry contacts), 6 inputs | ||||||||
I/O device | Input device for receving alarms, 14 inputs | ||||||||
I/O device | Output device for operating relays, 1 relay | ||||||||
I/O device | Output device for operating relays, 2 relays | ||||||||
I/O device | Output device for operating relays, 4 relays * | ||||||||
I/O device | Output device for operating relays, 9 relays |
- * When using the TKIE kit, 4 relays are achieved by combining the TKIE kit with the TA-10 module.
- *** Four inputs can be combined in a matrix function, providing 15 inputs/call buttons. This is supported in SIP mode and Edge mode only.