Actions

Logging (VS-Operator)

From Zenitel Wiki

Revision as of 16:48, 7 November 2023 by Asle (talk | contribs)
AI.png

This article shows how to configure the logging feature in the VS-Operator.

In the VSOP Client, select Filter sets, and Add a filter set for Station, and in the Caption field assign a descriptive name to the filter set, e.g. "Journal".

Information can be logged into the onscreen journal (Show) and to disk (Log).

Configuring Filter Set "Journal" for logging. Here "Call Received from <number> <name>" is logged when a call request is received



The text to send to the log is defined in the field Message text.

Here are some examples that can be used

Event Text in "Message text" field Information Level Comment
On CallRequest Add Call received from %DIRA %ACAPTION Info Triggered when a Ringing Group call (or Call Request) is received
On CallRequest Remove Call from %DIRA %ACAPTION removed from queue Info Triggered when a call is removed from the call queue
OnConnect Conversation with %DIRB %BCAPTION Info Triggered when a conversation is established
OnDisconnect Conversation with %DIRB %BCAPTION ended Info Triggered when a conversation is terminated
OnError Device error at %DIRA %ACAPTION Alarm Triggered when a station or device is reported faulty
On Custom params Door Opening triggered at %DIRA %ACAPTION Warning Triggers on "custom parameter" send from ICX-AlphaCom when Door Opening is activated
On Custom word string <depends on the event> <depends on the event> Triggers on custom event



Output to the log when using the examples above




Configuring Filter Set for logging



Now change the mode of operation to Operational, and verify that the Journal displays the correct information: