Pin Description Comment
1 GPIO General Purpose In Out
2 5V+ 5 volt output
3 Ext speaker (8ohm) Connection for external 8 ohm loudspeaker
4 Ext speaker (8ohm) Connection for external 8 ohm loudspeaker
5 Int speaker (8ohm) Connection for internal 8 ohm loudspeaker
6 Int speaker (8ohm) Connection for internal 8 ohm loudspeaker
7 Relay CO Relay output, Common
8 Relay NO Relay output, Normal Open
9 Line in/Mic Audio input (positive)
10 Line in/Mic Audio input (negative)
11 GND Ground connector
Note icon

Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².


Note icon
  • Relay switching capacity: Max. 9 watt (Max voltage: 60VAC/60VDC. Max current: 160mA)
  • The 5V output can deliver TBA mA current maximum