MST - Mail to Station
From Zenitel Wiki
Syntax
MST <[(node)]> <destination phys. no> <source phys. no> <“mail-text”/mail-id> <[priority]>
- Node: 1-254 (optional)
- Destination phys. no: 1-552
- Source phys. no: 1-552
- Mail text: Free text (maximum 16 characters) in quotes, or Mail id: no 19-30 (see below)
- Priority: 1-255 (optional)
Mail id's:
Mail id | Mail Text |
---|---|
19 | Technical Alarm 1 |
20 | Technical Alarm 2 |
21 | Technical Alarm 3 |
22 | Power Supply 3 |
23 | Power Supply 2 |
24 | Power Supply 1 |
25 | Standby Active |
26 | Temperature Alarm |
27 | Board error |
28 | Line Error |
29 | Device Error |
30 | AGA Error |
Example
MST 47 0 "Temp. alarm" – Send textmessage "Temp.alarm" to station 47 MST (3) 47 0 "Temp. alarm" 160 – Send "Temp.alarm" with priority 160 to station 47 in node 3 MST 1 0 28 - Send line error (28) to station 1