IND - Indicator control for CRMIV LEDs, buzzer etc.
From Zenitel Wiki
Syntax
IND <phys.no> <key.no> <led.no/buzzer> <ind-type> [ON/OFF]
phys.no: 1-552 = The physical connection for the CRM IV station you are programming.
key.no: 1-100 = Single-touch keys See drawing on the next page for details
1023 = Buzzer
1024 = Display
led.no: Single-touch keys Buzzer Display
1 = Red LED 1 = Internal buzzer 1 = Backlight
2 = Green LED 2 = External buzzer (relay)
Indtype LEDs and display: Buzzers
1 = continuous (low priority) 1 = 1 bleep per 8 seconds (low priority)
2 = slow flash (medium priority) 2 = 1 bleep per 2 seconds (medium priority)
3 = fast flash (high priority) 3 = 4 bleeps per second (high priority)
4 = continuous (alarm priority)
See “multiple LED functions” below.
[state] OFF or ON (capital letters)
The brackets [ ] indicate that this command is optional.
If nothing is entered in this field, the indication is switched on/off along with the event.
By entering OFF, for example, you can set an indication to turn off when the event
turns on.
Example
IND 2 23 2 3 ON – Station 2, key 23, turn green led, fast flashing, ON