Feature: Set station volume
Default directory number: 783
Feature number: 38
Parameter 1: 0 (N/A)
Description: Set output level (0-9) on ASLT line board. Primarily to compensate for long wires. Dial: 783 + digit 0-9. Default level is 3.


The ASLT output level can also be set from the Users & Stations menu in AlphaPro. The relation between the 783 volume setting and AlphaPro setting is as follows:

AlphaPro  783+n  IP-station
--------  -----  ----------
 -14        0        1
 -12	
 -10	             2
  -8        1 
  -6	             3
  -4        2
  -2	             4
   0        3 
   2        4        5
   4        5
   6        6        6
   8        7
  10	             7
  12        8
  14	             8
  16        9 