CDC_STATE 0x00xx xx AMC 10.40
Message used for billing control. <br\>

CDC = Call Detail Control

1 CLOCK Time of "state" change.
2 UINT2 Connection Reference for this "dialing" sequence.
3 UINT1 State of billing sequence.<br\>1 START, user has initiated a feature requiring CDC (5 = feature dirno)<br\>2 ESTABLISHED, connection established, (5 = related feature dirno netref) <br\>3 DIGIT, user has dial a digit, pin code or PSTN dialing (5 = digit netref) <br\>4 ACTIVE, call is still active, will come every 10 second during connection<br\>5 DISCONNECT, CDC sequence ended.
4 NET_OBJ_REF A-station (billed station).
5 NET_OBJ_REF Netref related to state type, (Feature, B-station or digit)