Actions

Group Call - Increased volume

From Zenitel Wiki

Revision as of 10:20, 16 June 2009 by Roarl (talk) (New page: This article describes how to increase the volume of the gong signal, and set it back to normal when the group call is answered (or canceled). As from firmware version AMC 10.23 the volum...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

This article describes how to increase the volume of the gong signal, and set it back to normal when the group call is answered (or canceled).

As from firmware version AMC 10.23 the volume to a station can be changed by the data command VOL. By using 4 events the Event Handler, one can set a higher volume during the gong signal, and set it back to a normal level when the call is answered.

In the following example a door station (101) is making a group call with repeatative gong to group 4. The members in group 4 also needs to be members of UDP group 7. In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:


Event Owner: Station Id: Id: 1 (101 The Door)
Event type: 15 - Event Trigger Feature
When change to: ON
When related to: Id: 9534
Action: WUDD 2 0 $ER U15 U1 U1 U1 L101 U3 L9001

When a station starts to ring the volume is set to level 6, and when the ringing stops the volume is set to level 3.