%ges
From Zenitel Wiki
Format: %ges(station, previous-exclusion-station)
Return a station which is member of the Mutual exclusion group for station. The return value is a Physical_number. Returns ‘0’ if no more members in the Mutual exclusion group'.
- station is Physical_number 1 – 552
- previous-exclusion-station: Use 0 to get the first exclusion-station, or use output from previous call to get next station. Physical_number 0 – 552
Example of use: LOOP/ENDLOOP Useful_example
New in AMCD 11.0.1.1.
Back to Event_Handler#List_of_macros.