Actions

Difference between revisions of "AMC Unit numbers"

From Zenitel Wiki

Line 1: Line 1:
 +
Table 1: Normal (Compact) Unit Numbers
 +
{| border="1"
 +
|-
 +
!IC/DC !!  In/Out !!Unit Number !!BP msg repr.!! # units !!
 +
|-
 +
|IC || Out ||00h–1Fh ||00h–1Fh ||32 ||Output Resource Units connected to Channels 0…31, respectively
 +
|-
 +
|IC || Out ||20h–2Fh ||20h–2Fh ||16 ||Output Resource Units not connected to Channels
 +
|-
 +
|IC || Out ||30h–37h ||30h–37h || 8 ||Output Resource Broadcast Classes (from top)
 +
|-
 +
|IC || Out ||38h–3Bh ||38h–3Bh || 4 ||Output Resource Units with Fixed U# Mapping
 +
|-
 +
|IC || Out ||  —    ||3Ch–3Fh || 4 ||—reserved for extended Adressing prefixes—
 +
|-
 +
|IC || In  ||40h–5Fh ||40h–5Fh ||32 ||Input Resource Units connected to Channels 0…31, respectively
 +
|-
 +
|IC || In  ||60h–6Fh ||60h–6Fh ||16 ||Input Resource Units not connected to Channels
 +
|-
 +
|IC || In  ||70h–77h ||70h–77h || 8 ||Input Resource Broadcast Classes (from top)
 +
|-
 +
|IC || In  ||78h–3Bh ||78h–7Bh || 4 ||Input Resource Units with Fixed U# Mapping
 +
|-
 +
|IC || In  ||  —    ||7Ch–7Fh || 4 ||—reserved for extended Adressing prefixes—
 +
|-
 +
|DC || Out ||80h–9Fh ||80h–9Fh ||32 ||Direct Control of Output Part of Channels 0…31, respectively
 +
|-
 +
|DC || Out ||A0h–AFh ||A0h–AFh ||16 ||Output Res. Units connected to or being Direct Remote Control Outputs 0…15, respectively
 +
|-
 +
|DC || Out ||B0h–B7h ||B0h–B7h || 8 ||Output Res. Units connected to or being Direct Remote Control Outputs 64…71, respectively
 +
|-
 +
|DC || Out ||B8h–BBh ||B8h–BBh || 4 ||Output Resource Units with Fixed U# Mapping
 +
|-
 +
|DC || Out ||—      ||BCh–BFh || 4 ||—reserved for extended Adressing prefixes—
 +
|-
 +
|DC || In  ||C0h–DFh ||C0h–DFh ||32 ||Direct Control of Input Part of Channels 0…31, respectively
 +
|-
 +
|DC || In  ||E0h–EFh ||E0h–EFh ||16 ||Input Res. Units connected to or being Direct Remote Control Inputs 0…15, respectively
 +
|-
 +
|DC || In  ||F0h–F7h ||F0h–F7h || 8 ||Input Res. Units connected to or being Direct Remote Control Inputs 64…71, respectively
 +
|-
 +
|DC || In  ||F8h–FBh ||F8h–FBh || 4 ||Input Resource Units with Fixed U# Mapping
 +
|-
 +
|DC || In  ||  —    ||FCh–FFh || 4 ||—reserved for extended Adressing prefixes—
 +
|}
 +
 +
 +
 
Table 2: Extended Unit Numbers
 
Table 2: Extended Unit Numbers
  

Revision as of 13:02, 28 January 2008

Table 1: Normal (Compact) Unit Numbers

IC/DC In/Out Unit Number BP msg repr. # units
IC Out 00h–1Fh 00h–1Fh 32 Output Resource Units connected to Channels 0…31, respectively
IC Out 20h–2Fh 20h–2Fh 16 Output Resource Units not connected to Channels
IC Out 30h–37h 30h–37h 8 Output Resource Broadcast Classes (from top)
IC Out 38h–3Bh 38h–3Bh 4 Output Resource Units with Fixed U# Mapping
IC Out 3Ch–3Fh 4 —reserved for extended Adressing prefixes—
IC In 40h–5Fh 40h–5Fh 32 Input Resource Units connected to Channels 0…31, respectively
IC In 60h–6Fh 60h–6Fh 16 Input Resource Units not connected to Channels
IC In 70h–77h 70h–77h 8 Input Resource Broadcast Classes (from top)
IC In 78h–3Bh 78h–7Bh 4 Input Resource Units with Fixed U# Mapping
IC In 7Ch–7Fh 4 —reserved for extended Adressing prefixes—
DC Out 80h–9Fh 80h–9Fh 32 Direct Control of Output Part of Channels 0…31, respectively
DC Out A0h–AFh A0h–AFh 16 Output Res. Units connected to or being Direct Remote Control Outputs 0…15, respectively
DC Out B0h–B7h B0h–B7h 8 Output Res. Units connected to or being Direct Remote Control Outputs 64…71, respectively
DC Out B8h–BBh B8h–BBh 4 Output Resource Units with Fixed U# Mapping
DC Out BCh–BFh 4 —reserved for extended Adressing prefixes—
DC In C0h–DFh C0h–DFh 32 Direct Control of Input Part of Channels 0…31, respectively
DC In E0h–EFh E0h–EFh 16 Input Res. Units connected to or being Direct Remote Control Inputs 0…15, respectively
DC In F0h–F7h F0h–F7h 8 Input Res. Units connected to or being Direct Remote Control Inputs 64…71, respectively
DC In F8h–FBh F8h–FBh 4 Input Resource Units with Fixed U# Mapping
DC In FCh–FFh 4 —reserved for extended Adressing prefixes—


Table 2: Extended Unit Numbers

IC/DC In/Out Unit Number BP msg repr. # units
IC Out 100h–11Fh 3D00h–3D1Fh 32 Output Resource Units connected to Channels 32…63, respectively
IC Out 120h–16Fh 3D20h–3D6Fh 80 More Output Resource Units not connected to Channels
IC Out 170h–17Fh 3D70h–3D7Fh 16 More Output Resource Units not connected to Channels
IC In 180h–19Fh 7D00h–7D1Fh 32 Input Resource Units connected to Channels 32…63, respectively
IC In 1A0h–1EFh 7D20h–7DEFh 80 More Input Resource Units not connected to Channels
IC In 1F0h–1FFh 7DF0h–7D7Fh 16 More Input Resource Units not connected to Channels
DC Out 200h–21Fh BD00h–BD1Fh 32 Direct Control of Output Part of Channels 32…63, respectively
DC Out 220h–24Fh BD20h–BD4Fh 48 Output Resource Units connected to or being Direct Remote Control Outputs 16…63, respectively
DC Out 250h–257h BD50h–BD57h 8 Output Resource Units with Fixed U# Mapping.
DC Out 258h–27Fh BD58h–BD7Fh 40 —Reserved for future use—
DC In 280h–29Fh FD00h–FD1Fh 32 Direct Control of Input Part of Channels 32…63, respectively
DC In 2A0h–2CFh FD20h–FD4Fh 48 Input Resources connected to or being Direct Remote Control Inputs 16…63, respectively
DC In 2D0h–2D7h FD50h–FD57h 8 Input Resource Units with Fixed U# Mapping.
DC In 2D8h–2FFh FD58h–FD7Fh 40 —Reserved for future use—
IC
Indirect Control, via backplane message
DC
Direct Control, memory write to SBI