Actions

AMC Unit numbers

From Zenitel Wiki

Revision as of 12:53, 28 January 2008 by Egil (talk)

Table 2: Extended Unit Numbers

IC/DC In/Out Unit Number BP msg repr. # units
IC Out 100h–11Fh 3D00h–3D1Fh 32 Output Resource Units connected to Channels 32…63, respectively
IC Out 120h–16Fh 3D20h–3D6Fh 80 More Output Resource Units not connected to Channels
IC Out 170h–17Fh 3D70h–3D7Fh 16 More Output Resource Units not connected to Channels
IC In 180h–19Fh 7D00h–7D1Fh 32 Input Resource Units connected to Channels 32…63, respectively
IC In 1A0h–1EFh 7D20h–7DEFh 80 More Input Resource Units not connected to Channels
IC In 1F0h–1FFh 7DF0h–7D7Fh 16 More Input Resource Units not connected to Channels
DC Out 200h–21Fh BD00h–BD1Fh 32 Direct Control of Output Part of Channels 32…63, respectively
DC Out 220h–24Fh BD20h–BD4Fh 48 Output Resource Units connected to or being Direct Remote Control Outputs 16…63, respectively
DC Out 250h–257h BD50h–BD57h 8 Output Resource Units with Fixed U# Mapping.
DC Out 258h–27Fh BD58h–BD7Fh 40 —Reserved for future use—
DC In 280h–29Fh FD00h–FD1Fh 32 Direct Control of Input Part of Channels 32…63, respectively
DC In 2A0h–2CFh FD20h–FD4Fh 48 Input Resources connected to or being Direct Remote Control Inputs 16…63, respectively
DC In 2D0h–2D7h FD50h–FD57h 8 Input Resource Units with Fixed U# Mapping.
DC In 2D8h–2FFh FD58h–FD7Fh 40 —Reserved for future use—
IC
Indirect Control, via backplane message
DC
Direct Control, memory write to SBI