Actions

Difference between revisions of "Account Settings (Pulse)"

From Zenitel Wiki

Line 12: Line 12:
 
*'''Authentication User Name''': This is the authentication user name used to register the station to the SIP server. This is required only if the SIP server requires authentication and is normally the same as the SIP ID.
 
*'''Authentication User Name''': This is the authentication user name used to register the station to the SIP server. This is required only if the SIP server requires authentication and is normally the same as the SIP ID.
 
*'''Authentication Password''': The authentication user password used to register the station to the SIP server. This is required only if the SIP server requires authentication
 
*'''Authentication Password''': The authentication user password used to register the station to the SIP server. This is required only if the SIP server requires authentication
*'''Register Interval''': This parameter specifies how often the station will register, and reregister in the SIP domain. This parameter will affect the time it takes to detect that a connection to a SIP domain is lost. Enter the values in number of seconds from 60 to 999999. The default interval is 600 seconds.
+
*'''Register Interval''': This parameter specifies how often the station will register, and reregister at the Pulse Server. This parameter will affect the time it takes to detect that a connection to the Pulse Server is lost. Enter the values in number of seconds from 60 to 999999. The default interval is 600 seconds.
 
*'''Restart If Not Registered [INCA only]''': If the station looses its registration towards the SIP server, the station can be forced to reboot after the preset time
 
*'''Restart If Not Registered [INCA only]''': If the station looses its registration towards the SIP server, the station can be forced to reboot after the preset time
  
  
 
[[Category: SIP intercom - Configuration]]
 
[[Category: SIP intercom - Configuration]]

Revision as of 15:59, 23 June 2017

Pulse icon 300px.png

On an IP Station in Pulse mode, select SIP Configuration > SIP Settings to access the page for configuring the Account Settings.

The Account Settings in Pulse mode


  • Display Name: Enter a name that will be shown on the display, and used as Caller ID.
  • Directory Number (SIP ID): This is the the phone number for the station.
  • Server Domain (SIP): The IP address of the Pulse Server
  • Backup Domain (SIP): Not in use
  • Backup Domain 2 (SIP): Not in use
  • Authentication User Name: This is the authentication user name used to register the station to the SIP server. This is required only if the SIP server requires authentication and is normally the same as the SIP ID.
  • Authentication Password: The authentication user password used to register the station to the SIP server. This is required only if the SIP server requires authentication
  • Register Interval: This parameter specifies how often the station will register, and reregister at the Pulse Server. This parameter will affect the time it takes to detect that a connection to the Pulse Server is lost. Enter the values in number of seconds from 60 to 999999. The default interval is 600 seconds.
  • Restart If Not Registered [INCA only]: If the station looses its registration towards the SIP server, the station can be forced to reboot after the preset time