Difference between revisions of "AlphaPro 12 - Error messages"
From Zenitel Wiki
(Created page with "If AlphaPro is not able to communictae with the AlphaCom server, there are several possible reasons: AlphaPro 12 error messages: * Wrong username/password for logging in (The...") |
|||
Line 2: | Line 2: | ||
AlphaPro 12 error messages: | AlphaPro 12 error messages: | ||
− | * | + | * '''The remote server returned an error''': (401) Unauthorized: Wrong username/password for logging in |
− | * Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom | + | * '''Unable to connect to the remote server''': Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom |
− | + | * '''The remote server returned an error: (404) Not Found''': AlphaPro v.12 is used towards AlphaCom v. 11. | |
− | + | * '''The remote server returned an error: (500) Internal Server Error''': The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a redundant system with two AlphaCom servers) | |
− | + | * '''Unable to connect to x.x.x.x''' (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only) | |
− | + | * '''Unable to connect to the remote server''': TCP port 80 (HTTP) is disabled in Filters setting in Web interface |
Revision as of 11:43, 18 December 2019
If AlphaPro is not able to communictae with the AlphaCom server, there are several possible reasons:
AlphaPro 12 error messages:
- The remote server returned an error: (401) Unauthorized: Wrong username/password for logging in
- Unable to connect to the remote server: Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom
- The remote server returned an error: (404) Not Found: AlphaPro v.12 is used towards AlphaCom v. 11.
- The remote server returned an error: (500) Internal Server Error: The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a redundant system with two AlphaCom servers)
- Unable to connect to x.x.x.x (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only)