AlphaPro 12 error messages:
 
AlphaPro 12 error messages:
* Wrong username/password for logging in (The remote server returned an error: (401) Unauthorized)
+
* '''The remote server returned an error''': (401) Unauthorized: Wrong username/password for logging in
* Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom (Unable to connect to the remote server)
+
* '''Unable to connect to the remote server''': Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom
* AlphaPro v.12 is used towards AlphaCom v. 11. (The remote server returned an error: (404) Not Found)
+
* '''The remote server returned an error: (404) Not Found''': AlphaPro v.12 is used towards AlphaCom v. 11.
* The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server i et redundant system med to AlphaComer) (The remote server returned an error: (500) Internal Server Error)
+
* '''The remote server returned an error: (500) Internal Server Error''': The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a redundant system with two AlphaCom servers)
* TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (SendAll/SendChg only) (Unable to connect to x.x.x.x)
+
* '''Unable to connect to x.x.x.x''' (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only)
* TCP port 80 (HTTP) is disabled in Filters setting in Web interface (Unable to connect to the remote server)
+
* '''Unable to connect to the remote server''': TCP port 80 (HTTP) is disabled in Filters setting in Web interface

Revision as of 11:43, 18 December 2019

If AlphaPro is not able to communictae with the AlphaCom server, there are several possible reasons:

AlphaPro 12 error messages:

  • The remote server returned an error: (401) Unauthorized: Wrong username/password for logging in
  • Unable to connect to the remote server: Incorrect IP address in AlphaPro (Exchange & System > System) - The IP address doesn't match the IP address of the AlphaCom
  • The remote server returned an error: (404) Not Found: AlphaPro v.12 is used towards AlphaCom v. 11.
  • The remote server returned an error: (500) Internal Server Error: The AlphaCom has "Standby Stations" licenses installed (which is the case when the the AlphaCom is used as a standby server in a redundant system with two AlphaCom servers)
  • Unable to connect to x.x.x.x (x.x.x.x is the IP address): TCP port 60001 ("AlphaPro") is disabled in Filters setting in Web interface (Applies to SendAll/SendChg operations only)
  • Unable to connect to the remote server: TCP port 80 (HTTP) is disabled in Filters setting in Web interface