Actions

Difference between revisions of "CALL SETUP"

From Zenitel Wiki

Line 7: Line 7:
 
|-
 
|-
 
|colspan="2"|'''$CALL L101 L102''' <br\> '''$CALL L101 L102 W32''' <BR\> '''$CALL L101 L102 W64
 
|colspan="2"|'''$CALL L101 L102''' <br\> '''$CALL L101 L102 W32''' <BR\> '''$CALL L101 L102 W64
|colspan="3" |Let 101 call 102 <BR\> Let 101 call, ignore if 102 forwards <br\> Let 101 call 102, force both 101 and 102
+
|colspan="3" |''Let 101 call 102'' <BR\> ''Let 101 call, ignore if 102 forwards'' <br\> ''Let 101 call 102, force both 101 and 102''
 
|-
 
|-
|colspan="5"|Set the timer of a mail queue entry. <BR\> When timeout, the event MAIL_TIMEOUT is generated. 10 seconds later the mail queue entry will be deleted automatically.  (All new mails are initialized by the AMC to max timer.)
+
|colspan="5"|$CALL_SETUP sets up a conversation like dialing from a station. Default behavior:
 +
* A station is disconnected if busy
 +
* Call can result in Private ringing, Absent, Busy or Transfer like a ordinary call
 +
* The A station's call priority in NVRAM is used.
 +
* No acknowledge messages are returned
 +
$CONN_REQUEST/$CONN is retained for compatibility only, DPMT_CALL_SETUP is the preferred message now.
 
|-
 
|-
 
|1||NET_OBJ_REF {ECL_STATION}||colspan="3"|Station.
 
|1||NET_OBJ_REF {ECL_STATION}||colspan="3"|Station.
Line 15: Line 20:
 
|2||UINT2||colspan="3"|Mail tag (unique id) for current queue entry.
 
|2||UINT2||colspan="3"|Mail tag (unique id) for current queue entry.
 
|-
 
|-
|3||UINT4
+
|3||UINT4||colspan="3"|Timeout value in seconds.<BR\>- The timer is ticked every 10 seconds.  This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is  655350 seconds, which is 7.5 days <BR\>- The system guarantees a minimum timeout as specified, worst case 10 seconds later.  Ex: setting 60 seconds generates timeout 60 - 69 seconds later.
|colspan="3"|Timeout value in seconds.<BR\>- The timer is ticked every 10 seconds.  This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is  655350 seconds, which is 7.5 days <BR\>- The system guarantees a minimum timeout as specified, worst case 10 seconds later.  Ex: setting 60 seconds generates timeout 60 - 69 seconds later.
 
 
|-
 
|-
 
|colspan="2"|Response:
 
|colspan="2"|Response:

Revision as of 11:14, 11 June 2007

CALL_SETUP 0x0008 8 AMC 08.20
$CALL L101 L102 <br\> $CALL L101 L102 W32 <BR\> $CALL L101 L102 W64 Let 101 call 102 <BR\> Let 101 call, ignore if 102 forwards <br\> Let 101 call 102, force both 101 and 102
$CALL_SETUP sets up a conversation like dialing from a station. Default behavior:
  • A station is disconnected if busy
  • Call can result in Private ringing, Absent, Busy or Transfer like a ordinary call
  • The A station's call priority in NVRAM is used.
  • No acknowledge messages are returned

$CONN_REQUEST/$CONN is retained for compatibility only, DPMT_CALL_SETUP is the preferred message now.

1 NET_OBJ_REF {ECL_STATION} Station.
2 UINT2 Mail tag (unique id) for current queue entry.
3 UINT4 Timeout value in seconds.<BR\>- The timer is ticked every 10 seconds. This means that the minimum timer value is 10 seconds, and longer times should be specified with last digit 0.<BR\>- The longest possible time is 655350 seconds, which is 7.5 days <BR\>- The system guarantees a minimum timeout as specified, worst case 10 seconds later. Ex: setting 60 seconds generates timeout 60 - 69 seconds later.
Response: COMMAND_RESPONSE