Actions

Difference between revisions of "CALL SETUP"

From Zenitel Wiki

Line 1: Line 1:
{| border:"solid black" cellspacing="0" cellpadding="3"
+
{| border="1" cellspacing="0" cellpadding="3"
 
|-
 
|-
!width="90pt" colspan="2"|CALL_SETUP
+
!style="background:#ffdead;" width="90pt" colspan="2"|CALL_SETUP
!width="100pt"|0x0008
+
!style="background:#ffdead;"width="100pt"|0x0008
!width="30pt"|8
+
!style="background:#ffdead;"width="30pt"|8
!width="100pt"|AMC 08.20
+
!style="background:#ffdead;"width="100pt"|AMC 08.20
 
|-
 
|-
 
|colspan="2"|'''$CALL L101 L102''' <br\> '''$CALL L101 L102 W32''' <BR\> '''$CALL L101 L102 W64
 
|colspan="2"|'''$CALL L101 L102''' <br\> '''$CALL L101 L102 W32''' <BR\> '''$CALL L101 L102 W64

Revision as of 17:23, 13 June 2007

CALL_SETUP 0x0008 8 AMC 08.20
$CALL L101 L102 <br\> $CALL L101 L102 W32 <BR\> $CALL L101 L102 W64 Let 101 call 102 <BR\> Let 101 call, ignore if 102 forwards <br\> Let 101 call 102, force both 101 and 102
$CALL_SETUP sets up a conversation like dialing from a station. Default behavior:
  • A station is disconnected if busy
  • Call can result in Private ringing, Absent, Busy or Transfer like a ordinary call
  • The A station's call priority in NVRAM is used.
  • No acknowledge messages are returned

$CONN_REQUEST/$CONN is retained for compatibility only, DPMT_CALL_SETUP is the preferred message now.

1 NET_OBJ_REF<br\>{ECL_STATION, <BR\> ECL_USER} A - user or station.
2 NET_OBJ_REF <br\>{ECL_STATION, <BR\> ECL_USER} B - user or station
3 UINT2<br\>(optional) Call mode options (default zero)<br\>Call mode options can be the sum of the following:<BR\>

1: Return CONN_REFERENCE, STATION_DOWN or STATION_BUSY. Send DISCONNECTED at disconnect (CSF_RETURN_ACK)<BR\> 2: Require CONN_REF_ACK and DISCONNECTED_ACK (CSF_3WAY_ACK)<BR\> 4: Reserved<BR\> 8: Reserved<BR\> 16: Do not disconnect A station if busy (CSF_NOT_FORCE_A)<BR\> 32: Do not follow call forwarding (CSF_NO_FORWARD)<BR\> 64: Transfer call, answer group call (CSF_TRANSFER_CALL) Forces both A and B stations.<BR\> 128: Force call in Open Duplex mode (CSF_OPEN_DUPLEX) (AMC 09.03)

4 UINT1<BR\>(optional) A-call priority 1 - 4. Zero or omitted means that the NVRAM priority of A station is used
5 UINT1<br\>(optional) B-call priority 1 - 4. Zero or omitted means that the NVRAM priority of A station is used
6 NET_OBJ_REF<br\>{ECL_STATION}<br\>(optional) B Station if User B is not at own station.
Response CONN_REFERENCE, STATION_DOWN or STATION_BUSY, or none