Actions

Difference between revisions of "CDC CMD"

From Zenitel Wiki

Line 22: Line 22:
 
|-
 
|-
 
|align=center|4||[[UINT1]]||colspan="3"|Abort reason code <br>
 
|align=center|4||[[UINT1]]||colspan="3"|Abort reason code <br>
1 Invalid Pin Code <br>
+
1 INVALID_PIN <br>
2 Barred Number <br>
+
2 BARRED_NUMBER <br>
3 Account Overdrawn <br>
+
3 ACCOUNT_OVERDRAWN <br>
4 No (SQL) Trunk <br>
+
4 NO_SQL_TRUNK <br>
5 No (SQL) Extension <br>
+
5 NO_SQL_EXTENSION <br>
 
|-
 
|-
 
|align=center|5||[[UINT1]]||colspan="3"|number of digits to delete from out-buffer
 
|align=center|5||[[UINT1]]||colspan="3"|number of digits to delete from out-buffer

Revision as of 15:33, 10 June 2008

Related to ABSD_Billing

CDC_CMD 0x009F 159 AMC 10.40
Message used for billing control. <br\>

Call Detail Control message, response to CDC_STATE. command. Used from ABSD towards AMCD

1 UINT2 Connection Reference for this "dialing" sequence (actually ST_IND of A-station).
2 NET_OBJ_REF A-station (billed station) .
3 UINT1 Command

1 DIAL_PIN, (dial pin code , display *)
2 DIAL_NORMAL
3 TRUNK_SET, Set trunk number for SIP, start SIP connection.
4 ABORT , Pin code etc. is not OK, barred number or account overdrawn. Expect CDC_STATUS(DISCONNET) in return

4 UINT1 Abort reason code

1 INVALID_PIN
2 BARRED_NUMBER
3 ACCOUNT_OVERDRAWN
4 NO_SQL_TRUNK
5 NO_SQL_EXTENSION

5 UINT1 number of digits to delete from out-buffer
6 NET_OBJ_REF For TRUNK_SET: Trunknumber
7 TEXT16 Additonal info as text (Abort reason, user name).

Back to AlphaNet message list