Actions

Difference between revisions of "Cold Start of AMC-IP"

From Zenitel Wiki

(Cold start procedure)
(Modify Factory Default Settings)
 
(27 intermediate revisions by 4 users not shown)
Line 1: Line 1:
==Perform Cold Start==
+
{{A}}
 +
Performing a '''cold start''' of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
  
A cold start of the AMC-IP board will delete all previous
+
===Cold start procedure===
programming, load the default database and set the default IPaddress
+
[[Image:Cold Start of AMC-IP.jpg|right|130px|thumb|Cold start to load default factory settings]]
to 169.254.1.5 with mask 255.255.0.0 on Eth0.
+
*Turn the exchange mains switch ON (on the back of the cabinet).
See section 2.4 for factory default settings.
+
*Hold the [[AMC-IP#LED indicators|cold start button]] on the [[AMC-IP]] board depressed.
 +
*Press the reset button on the [[APC]] card briefly. (On the E7 exchange, the reset button is located on the power card.)
 +
*Keep the cold start button pressed at least 2 sec. after reset. The AMC status LED will blink green when the boot is ready.
 +
 
 +
<br/><br/>
 +
=== Cold-start of AMC application only, keep IP setting ===
 +
[[Image:Cold Start of AMC-IP.2.jpg|right|130px|thumb|Cold-start of AMC application]]
 +
*Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
 +
*After 10 sec., press the cold start button on the AMC-IP board.
 +
*Keep cold start button pressed until AMC running LED is blinking green.
 +
><br/><br/>
 +
 
 +
== Modify Factory Default Settings ==
 +
After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the [[AlphaPro]] programming tool must be used.
  
===Cold start procedure===
+
[[Category:Factory Default]
[[Image:Cold Start of AMC-IP.jpg|right|250px|thumb]]
 
*Turn the exchange mains switch ON (on the back of the
 
cabinet).
 
*Hold the cold start button on the AMC-IP board depressed.
 
*Press the reset button on the APC card briefly.
 
(On the E7 exchange, the reset button is located on the power
 
card.)
 
*Keep the cold start button pressed at least 1 sec. after reset.
 
The AMC status LED will blink green when the boot is ready.
 

Latest revision as of 08:05, 9 August 2019

AlphaCom icon 300px.png

Performing a cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.

Cold start procedure

Cold start to load default factory settings
  • Turn the exchange mains switch ON (on the back of the cabinet).
  • Hold the cold start button on the AMC-IP board depressed.
  • Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
  • Keep the cold start button pressed at least 2 sec. after reset. The AMC status LED will blink green when the boot is ready.



Cold-start of AMC application only, keep IP setting

Cold-start of AMC application
  • Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
  • After 10 sec., press the cold start button on the AMC-IP board.
  • Keep cold start button pressed until AMC running LED is blinking green.

>

Modify Factory Default Settings

After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the AlphaPro programming tool must be used.

[[Category:Factory Default]