Actions

Difference between revisions of "Cold Start of AMC-IP"

From Zenitel Wiki

(Modify Factory Default Settings)
 
(4 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
{{A}}
 
Performing a '''cold start''' of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
 
Performing a '''cold start''' of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.
  
Line 6: Line 7:
 
*Hold the [[AMC-IP#LED indicators|cold start button]] on the [[AMC-IP]] board depressed.
 
*Hold the [[AMC-IP#LED indicators|cold start button]] on the [[AMC-IP]] board depressed.
 
*Press the reset button on the [[APC]] card briefly. (On the E7 exchange, the reset button is located on the power card.)
 
*Press the reset button on the [[APC]] card briefly. (On the E7 exchange, the reset button is located on the power card.)
*Keep the cold start button pressed at least 1 sec. after reset. The AMC status LED will blink green when the boot is ready.
+
*Keep the cold start button pressed at least 2 sec. after reset. The AMC status LED will blink green when the boot is ready.
  
 
<br/><br/>
 
<br/><br/>
Line 19: Line 20:
 
After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the [[AlphaPro]] programming tool must be used.
 
After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the [[AlphaPro]] programming tool must be used.
  
[[Category:AlphaCom E Software]]
+
[[Category:Factory Default]

Latest revision as of 08:05, 9 August 2019

AlphaCom icon 300px.png

Performing a cold start of the AMC-IP board will delete all previous programming, load factory default settings and set the IP-address to 169.254.1.5 with mask 255.255.0.0 on Eth0.

Cold start procedure

Cold start to load default factory settings
  • Turn the exchange mains switch ON (on the back of the cabinet).
  • Hold the cold start button on the AMC-IP board depressed.
  • Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
  • Keep the cold start button pressed at least 2 sec. after reset. The AMC status LED will blink green when the boot is ready.



Cold-start of AMC application only, keep IP setting

Cold-start of AMC application
  • Press the reset button on the APC card briefly. (On the E7 exchange, the reset button is located on the power card.)
  • After 10 sec., press the cold start button on the AMC-IP board.
  • Keep cold start button pressed until AMC running LED is blinking green.

>

Modify Factory Default Settings

After cold start the system is set up with a default program and is working without any further programming. To change or add to the default settings, the AlphaPro programming tool must be used.

[[Category:Factory Default]