For server end connection details see [[ASLT - AlphaCom Subscriber Line Board]]
+
The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:
 +
* 0.5 mm wires: 1.4 km
 +
* 0.6 mm wires: 2.0 km
 +
* 0.9 mm wires: 4.0 km
  
[[image:AnalogueStationConnection1.png|left|400px|]]
+
[[image:WiringAnalog1.png|left|800px|]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
 +
{{note| The [[Station cable for 4 wire analogue station|station cable]] is not a 1:1 cable! }}
 +
 +
For details on connection at the AlphaCom server side, see [[ASLT - AlphaCom Subscriber Line Board]]
 +
 +
<br>
  
 
==Dimensional Drawing==
 
==Dimensional Drawing==

Revision as of 13:53, 15 August 2018

AlphaCom icon 300px.png
Desk Master Station 100 7034 210

Highlights

  • Combined wall and desk master station with full access to all features in the Vingtor-Stentofon AlphaCom exchange
  • Easy operation via ten direct access keys
  • Superb audio quality
  • Handset for confidential conversation
  • Selectable private / open mode


Wiring

The cabling from the AlphaCom server to the intercom station is star wiring. Two twisted pairs of wires are required. The maximum distance depends on the cable diameter:

  • 0.5 mm wires: 1.4 km
  • 0.6 mm wires: 2.0 km
  • 0.9 mm wires: 4.0 km
WiringAnalog1.png


Note icon The station cable is not a 1:1 cable!


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board