Actions

Device Profiles

From Zenitel Wiki

Edge-icon.jpg

This article described how to configure the Device Profiles in an IC-EDGE System.

The Device Profiles defines a set of features that are available for a group of stations.

The IC-EDGE system has five device profiles:

  • Profile 1 - Default
  • Profile 2 - Substation
  • Profile 3 - Display station
  • Profile 4 - Operator
  • Profile 5 - Gateway

The following features are included in a device profile:

  • Outgoing call restriction
  • Relay activation (i.e. Door opening)
  • Group Call initiation
  • Busy Override

To modify device profiles select Edge Controller > Device Profiles:

Modify Device Profiles.


  • Profile nickname: The name of the profile. Any text can be used.
  • Outgoing calls allowed: Stations in selected profile can call stations in the checked profiles. «Forbidden» in the display if access is denied.
  • Relay activation allowed: Stations in selected profile can activate the relay (e.g. Door Opening) on stations in the checked profiles.
  • Group calls allowed: Stations in selected profile are allowed to dispatch the checked group calls
  • Busy override allowed: When calling a busy station, stations in selected profile can force a connection by pressing digit 5. This function can only be used from Zenitel Intercoms, including Turbine and INCA family and Zenitel-Client. 3rd party SIP stations and ITSV's does not support this