Actions

Difference between revisions of "Door Opening - During Conversation (Event Type)"

From Zenitel Wiki

 
(15 intermediate revisions by 5 users not shown)
Line 1: Line 1:
 +
{{AI}}
 
==Event description==
 
==Event description==
  
 
{|  
 
{|  
 
|-
 
|-
|width="100pt"|'''Event Owner''':
+
|width="150pt"|'''Event Owner''':
|width="300pt"|A station
+
|width="300pt"|The door station
 
|-
 
|-
 
|'''Event type''': || 02 – Door Opening - During Conversation
 
|'''Event type''': || 02 – Door Opening - During Conversation
Line 10: Line 11:
 
|'''Subevent''': || N/A
 
|'''Subevent''': || N/A
 
|-
 
|-
|'''When change to ON''': || When digit 6 is pressed during conversation (actually when the digit key is released)
+
|'''When change to ON''': || When [[Activate RCO output at remote station feature|digit 6]] is pressed during conversation (actually when the digit key is released)
 
|-
 
|-
|'''When change to OFF''': || 3.5 sec later(RCO Pulse time)
+
|'''When change to OFF''': || 3.5 sec later ([[Exchange_%26_System_%28AlphaPro%29#Timers|RCO Pulse time]], programmable)
 
|-
 
|-
 
|'''When related to''': || The door control station
 
|'''When related to''': || The door control station
 
|-
 
|-
 
|}
 
|}
<br><br><br>
+
<br>
  
==Event description==
+
The action is on the owner, when digit 6 is pressed on the related station. The event reports an ON and an OFF transition. ON when digit 6 is pressed on the related station, OFF after a period as set for the timer ‘RCO pulse time’. If 'Related to' is not defined, all stations can open the door. If 'Related to' is defined only the related station (either single or part of a UDP-group) can open the door.
 +
 
 +
==Application==
 +
* Remote [[door opening]]
  
{| border="1" cellpadding="4"
+
==Example==
! align="left"|[[Event Owner]]:
+
This example shows directory number 101 activating RCO 14 when pressing digit 6 during conversation with Door Station 114.
| The door station
 
|-
 
! align="left"|[[Event Handler#Events Types - Grouped by Function|Event type]]:
 
| 02 - Door Opening - During Conversation
 
|-
 
! align="left"|[[Sub-Event (Event Handler)|Sub-Event]]:
 
| N/A
 
|-
 
! align="left"|[[When Change to (Event Handler)|When Change to ON]]:
 
| Digit 6 during conversation (digit 6 release)
 
|-
 
! align="left"|[[When Change to (Event Handler)|When Change to OFF]]:
 
| 3.5 sec later(RCO Pulse time)
 
|-
 
! align="left"|[[When Related to (Event Handler)|When Related to]]:
 
| the door control station
 
|-
 
|}
 
  
*Application
+
[[File:RCO1.PNG|thumb|left|500px]]
:- Remote door opening
+
<br style="clear:both;" />
  
 
[[Category:Event Handler]]
 
[[Category:Event Handler]]
 +
[[Category:Event types]]

Latest revision as of 16:12, 4 October 2019

AI.png

Event description

Event Owner: The door station
Event type: 02 – Door Opening - During Conversation
Subevent: N/A
When change to ON: When digit 6 is pressed during conversation (actually when the digit key is released)
When change to OFF: 3.5 sec later (RCO Pulse time, programmable)
When related to: The door control station


The action is on the owner, when digit 6 is pressed on the related station. The event reports an ON and an OFF transition. ON when digit 6 is pressed on the related station, OFF after a period as set for the timer ‘RCO pulse time’. If 'Related to' is not defined, all stations can open the door. If 'Related to' is defined only the related station (either single or part of a UDP-group) can open the door.

Application

Example

This example shows directory number 101 activating RCO 14 when pressing digit 6 during conversation with Door Station 114.

RCO1.PNG