Event description

Event Owner: The door station
Event type: 02 – Door Opening - During Conversation
Subevent: N/A
When change to ON: When digit 6 is pressed during conversation (actually when the digit key is released)
When change to OFF: 3.5 sec later (RCO Pulse time, programmable)
When related to: The door control station


The action is on the owner, when digit 6 is pressed on the related station. The event reports an ON and an OFF transition. ON when digit 6 is pressed on the related station, OFF after a period as set for the timer ‘RCO pulse time’. If 'Related to' is not defined, all stations can open the door. If 'Related to' is defined only the related station (either single or part of a UDP-group) can open the door.

Application

Example

This example shows directory number 101 activates RCO 14 when pressing digit 6 during conversation with Door Station 114.

RCO1.PNG