Door Opening - During Conversation (Event Type)
From Zenitel Wiki
Event description
Event Owner: | The door station |
Event type: | 02 – Door Opening - During Conversation |
Subevent: | N/A |
When change to ON: | When digit 6 is pressed during conversation (actually when the digit key is released) |
When change to OFF: | 3.5 sec later (RCO Pulse time, programmable) |
When related to: | The door control station |
The action is on the owner, when digit 6 is pressed on the related station. The event reports an ON and an OFF transition. ON when digit 6 is pressed on the related station, OFF after a period as set for the timer ‘RCO pulse time’. If 'Related to' is not defined, all stations can open the door. If 'Related to' is defined only the related station (either single or part of a UDP-group) can open the door.
Application
- Remote door opening
Example
This example shows directory number 101 activating RCO 14 when pressing digit 6 during conversation with Door Station 114.