Door opening of Ring Master stations from AlphaCom
From Zenitel Wiki
Revision as of 11:51, 24 May 2011 by Asle (talk) (moved Door Open Function to Door opening of Ring Master stations from AlphaCom)
Door opening of Ring Master stations from AlphaCom is configured by using Event During Connection and DP message DTMF_CONN
Example
Node 1 AlphaCom
- Station 101 is a Control Room Station
- Station 104 is a Door Station
Node 3 Ring Master
- Door Station Directory number "4567"
Event During Connection configured as directory number "6" (Door opening)
The Event Handler is configured with 2 events:
Event 1: This event will send DTMF tone 5 if digit "6" is pressed during conversation to "4567".
Event Owner: | Station Id: 1 |
Event type: | 15 - Event Trigger Feature |
Subevent: | 0 |
When change to: | ON or OFF |
When related to: | Node: 3, Directory Number, Id: 4567 |
Action: | $DTMF_CONN L%1.dir U5 |
Event 2:The second event will toggle the RCO pin 4 for 1 second if digit "6" is pressed during conversation to door station number 104.
Event Owner: | Station Id: 1 |
Event type: | 15 - Event Trigger Feature |
Subevent: | 0 |
When change to: | ON or OFF |
When related to: | Directory Number, Id: 104 |
Action: | RCO 4 ON U10 |