Actions

Difference between revisions of "Event Trigger (Event Type)"

From Zenitel Wiki

(Event description)
(Subevents)
Line 25: Line 25:
  
 
== Subevents ==
 
== Subevents ==
:- Default = 0. Possible to use param1 for feature 52 and 85. This can be used to group event triggers by filtering on subevent type.
+
*The parameter-attribute of the Event Trigger directory number (52/n or 85/n) must match the sub-event
 +
*Example: Feature 85/2 will trigger event type 15, sub-event 2
 +
*The parameter-attribute can be used to group event triggers by filtering on subevent type
  
 
==Additional information==
 
==Additional information==

Revision as of 23:53, 14 November 2007

Event description

Event Owner: A station or UDP group
Event type: 15 - Event trigger feature
Subevent: See below
When change to ON: When dialing a dirno with feat. 52, 85, 95 or 105
When change to OFF: When feature 95 or 105 disconnects
When related to: The event trigger directory number

Event triggers

- Feature 52 (9534): Event trigger without cancel tone
- Feature 85 (9533): Event trigger with cancel tone
- Feature 95 (9535): Event trigger with directory number parameter
- Feature 105 (9545): Event trigger with digit parameter

Subevents

  • The parameter-attribute of the Event Trigger directory number (52/n or 85/n) must match the sub-event
  • Example: Feature 85/2 will trigger event type 15, sub-event 2
  • The parameter-attribute can be used to group event triggers by filtering on subevent type

Additional information

- Feature 52 and 85 only triggers the ON event

Application

- Any function or combination of functions which is not supported by the standard features in the AlphaCom