Actions

Difference between revisions of "Event Trigger (Event Type)"

From Zenitel Wiki

(Application)
(Additional information)
Line 29: Line 29:
 
*The parameter-attribute can be used to group event triggers by filtering on subevent type
 
*The parameter-attribute can be used to group event triggers by filtering on subevent type
  
==Additional information==
+
 
* Feature 52 and 85 only triggers the ON event
 
  
 
==Application==
 
==Application==

Revision as of 23:55, 14 November 2007

Event description

Event Owner: A station or UDP group
Event type: 15 - Event trigger feature
Subevent: See below
When change to ON: When dialing a dirno with feat. 52, 85, 95 or 105
When change to OFF: When feature 95 or 105 disconnects
When related to: The event trigger directory number

Event triggers

  • Feature 52 (9534): Event trigger without cancel tone
  • Feature 85 (9533): Event trigger with cancel tone
  • Feature 95 (9535): Event trigger with directory number parameter
  • Feature 105 (9545): Event trigger with digit parameter

Subevents

  • The parameter-attribute of the Event Trigger directory number (52/n or 85/n) must match the sub-event
  • Example: Feature 85/2 will trigger event type 15, sub-event 2
  • The parameter-attribute can be used to group event triggers by filtering on subevent type


Application

  • Any function or combination of functions which is not supported by the standard features in the AlphaCom