This article describes how to upgrade the software in Flowire device FCDC-3.

For upgrade procedure for FCDC-1 or FCDC-2, see here.

The upgrade can be done in two different ways:

  • Upgrade from the web interface of the Flowire unit
  • Upgrade by using the VS-IMT tool. Note that IMT version 1.6.3.0 or higher is required (pending)

Upgrading from the Web Interface

The Flowire unit are automatically assigned an IP address from the network if there is a DHCP server present. If there is no DHCP server on the network, the Flowire units will by default have a static IP address 169.254.1.10. In this case there will be multiple Flowire units with the same IP address on the network, and you need to isolate the Flowire unit which is going to be upgraded from the others in the network.

Isolating the Flowire units one by one


Although it is not necessary for the Flowire to perform its function, it is good practice to change the static IP to something unique at the same time, for easier maintenance in the future.

  • Download the latest software package (e.g. "vsf-fcdc3-1.0.3.2.zip") from the download site.
  • Unzip the files to a folder.
  • Use a standard web browser and enter the IP address of the Flowire (e.g. 169.254.1.10) in the address field. Default username/password: admin/alphaadmin
  • Navigate to Management > Update Software
  • Select Browse, and locate the image file vsf-fcdc3-<version>_fs_kernel
FCDC3 - Software Upgrade page


  • Select Update Software
  • The upgrade takes approx. 2 minutes. The web page will be reloaded when the FCDC3 is up and running again

Upgrading from the IMT tool

Note icon To upgrade the FCDC3 from the IMT tool, IMT version 1.6.3.0 or higher is required. This version is currently in the making.


Procedure: VS-IMT Upgrade Stations