Flowire clusters

From Zenitel Wiki

Revision as of 10:24, 26 August 2015 by Asle (talk)
Two Flowire clusters, each with one central FCDC1 Flowire Unit and one central Power Supply Unit (PSU). Cross talk must be preveneted between the clusters.

When there are several Flowire clusters in an installation, the different clusters must be separated to avoid crosstalk between the clusters. When crosstalk is present, a Flowire unit on one cluster might "jump over" to the other cluster, causing errors in the communication.

Cluster separation can be achieved in two ways:

  • Physical separation
  • Separation by NMK Password.

Physical separation

(both the Flowire units, the power cable, and the link cable). I don't have an exact distance for you, but crosstalk might appear if for instance the cables for two different clusters are running on each side of a wall...


Separation by NMK Password

When crosstalk is present, a flowire unit on one cluster might "jump over" to the other cluster, causing errors in the communication. When implementing different passwords, it will not be possible for a flowire unit to "jump" to a cluster with a different password.

In your case, if these 3 Flowires on the picture are on three different clusters, password separation is necessary, else you will have trouble for sure.

All Flowires within the same cluster must have same PW, else they cannot communicate.

HomePlugAV0123 is the default password.