Actions

Difference between revisions of "GSM Gateway (Edge)"

From Zenitel Wiki

(Call multiple phone numbers in sequence)
(Call multiple phone numbers in sequence)
Line 196: Line 196:
 
# Enable [[Advanced Configuration Mode (Edge)|Advanced Configuration Mode]]
 
# Enable [[Advanced Configuration Mode (Edge)|Advanced Configuration Mode]]
 
# Go to '''Edge Configuration''' > '''Direct Access Keys'''. Scroll down to the bottom of the page, and set '''Ringing Time''' to the interval you want.
 
# Go to '''Edge Configuration''' > '''Direct Access Keys'''. Scroll down to the bottom of the page, and set '''Ringing Time''' to the interval you want.
# As an option, one can have individual ringing time on each entry by adding ";'''ringing_time=xx'''" after the entry.
+
# As an option, one can have individual ringing time on each entry by adding ";'''ringing_time=xx'''" after the entry, e.g.:
 +
:: 40002547;pause=5;ringing_time=40
 +
::40002587;pause=5;ringing_time=30
 +
::40002556;pause=5;ringing_time=55
 +
::40002549
  
  

Revision as of 14:20, 19 May 2020

Edge-icon.jpg
The MV-370 GSM Gateway in an IC-EDGE System

This article describes the setup of the MV-370 GSM Gateway (item 220 0003 000) in an IC-EDGE System.

Prerequisites

  • An IC-EDGE System already installed
  • SIM card (mini-SIM size) for the gateway. You need to know the phone number and the PIN code for the SIM card.

Edge Controller configuration

Install license

The GSM Gateway requires that there is a valid Telephone Gateway license installed.

To insert a license:

License for one Telephone Gateway installed


Note icon
  • From factory there is a 60-day free license period during which Telephone Gateways can be used without the need of any license.
  • When the free license period expires there must be a valid license installed, if not the gateway will cease to operate


Create a SIP Account

A SIP Account must be created at the Edge Controller.

To add a new SIP account:

  • From Edge Controller > System Configuration > Directory, under the Manually Added Devices section, press the "+" button
  • Select Gateway from the dropdown list
  • Number: 0. This is the number to dial to get access the telephone line. Other number can be used.
  • Name: <name of your choice>
  • Profile: Optionally one can change the Profile. Device Profiles are used if restrictions should be applied to Relay Activation (Door Opening), Group Call activation etc.
  • Optionally one can add a SIP Password. If a password is entered, one have to also manually configure the same password in the gateway it self. The password is used for the registration proccess.
  • Press Save to store the new device in the Edge Controller
Adding a Telephone Gateway to the Edge System


GSM Gateway Configuration

Important: If you have a SIM card with PIN code activated, DO NOT insert the SIM card yet.

Load Factory Default values

The GSM Gateway comes with default network parameters (factory default parameters). The default IP address is 192.168.0.100.

You can load factory network parameters and reset the username and password to its default settings (username: voip, password: 1234) by following these steps:

  1. Press and hold the button SW1 located at the bottom of the unit (you have to remove the lid) for about 7-8 seconds
  2. Wait for the "Mobile" and "LAN" leds to start blinking
Set default IP Address: Press SW1 for 7-8 seconds



  • The GSM Gateway will now get the IP address 192.168.0.100, subnet mask 255.255.255.0.

Accessing the gateway

  • Change the IP address of your PC to 192.168.0.99, subnet mask 255.255.255.0.
  • Connect the LAN port of the PC to the Ethernet port of the GSM Gateway.
  • Start your Web Browser and type 192.168.0.100 in the URL field.
  • Type in username voip and password 1234. (Case-sensitive!)
Accessing the gateway



  • The Home page of the Web Interface will appear:
Homepage of the GSM Gateway


Network Configuration

To change the IP address of the GSM gateway, go to Network > WAN Settings, and enter:

  • IP Type: Fixed IP
  • Master IP: The IP address of this gateway. Must be in the IP address range of the subnet for the PULSE system
  • Mask: Subnet mask for the gateway. Other parameters are optional.
  • Press Submit, then Save. The gateway will restart.
Network settings


After having changed the IP Address of the gateway, follow these steps to re-access the gateway:

  • Change the IP address of your PC to match the new network settings of the gateway. The PC and Gateway must be on the same subnet.
  • Re-access the Gateway by typing the new assigned IP address in the URL field of your web browser.

SIP Parameters

To define the SIP settings, go to SIP Settings -> Service Domain:

  • Active = ON
  • Display Name: Any text
  • User Name: Enter the directory number used to access the gateway. This number must be identical to the number entered in the PULSE Server.
  • Proxy Server: Enter the IP address of the PULSE Server
  • Press Submit, then Save. The gateway will restart.
SIP Parameters


  • Status = Registered: Shows that the gateway is successfully registered to the PULSE server.

Mobile Settings

Go to Mobile > Settings and define the following parameters:

  • SIP From = Tel/User (Standard)
  • Mobile PIN Code = ON. Code: Enter the PIN code for the SIM card. Confirmed: Enter the PIN code again.
Mobile settings


The SIM card can now be inserted. The gateway uses Standard (Mini) SIM card (15x25mm).

SIM card placement


After the SIM card is inserted, you can check that the gateway is successfully registered to the GSM network in Mobile > Status.

Some parameters to look for are:

  • Operator = The telecom provider
  • Signal Quality = Shows the signal strength. The signal should be in the range of 10 - 31.
Gateway successfully registered to the GSM network


If these parameters does not show, your gateway is not registered to the GSM network. Check that SIM card is properly inserted, and that the PIN code is correctly entered.

TIP: Try the SIM card in a regular mobile phone.

Configure outgoing calls to the GSM network

To automatically dial an external phone number when gateway is accessed, go to Route > Lan To Mobile Settings.

On item 0, enter:

  • URL = *
  • Call Num = <external phone number to dial>
Outgoing calls routed to a fixed telephone number



If Call Num instead is set to "*", there will be 2-stage dialing. I.e. you will get a second dial tone after having dialed "0", and the gateway will wait for further digits.

Configure incoming calls from the GSM network

Alternative 1: Route incoming calls to a predefined number.

Select Route > Mobile to LAN Settings, and set:

  • CID = *
  • URL = <intercom number>
Incoming calls are routed to station number 12



Alternative 2: There will be a second dial-tone presented on incoming calls. The user must dial the intercom number. The dialing can be terminated by '#', or alternatively one can wait for 5 seconds and the call will be established.

Select Route > Mobile to LAN Settings, and set:

  • CID = *
  • URL = *
Selective incoming call



DTMF Input from outside line

During a conversation between a Pulse station and a telephone, the telephone operator can activate an output (e.g. trigger a relay for door opening) in the Pulse System by pressing a digit on the phone.

To enable digit actions from the telephone line during conversation, go to set SIP Settings > DTMF Setting, and enable "SIP INFO":

Set DTMF by 'SIP INFO'




Call multiple phone numbers in sequence

The Ringlist in the Edge system can be used to call several phone numbers in sequence. If the first number doesn't answer within a preset time, the call will be made to the second number, and so on. Intercom stations can also be included in the sequence. You can have up to seven different numbers in the ring list.

Call scenario examples:

  1. Call to an Intercom station > Phone number 1 > Phone number 2 in sequence, or
  2. Call Phone number 1 > Phone number 2 > Phone number 3 in sequence
Note icon
  • Turbine devices must have software version 5.1.3.0 or later
  • INCA devices must have software 2.11.3.0 or later


In the Edge Controller, Server Configuration > Directory, go to the Linked Edge Controllers section and define the number range for the phone numbers to call, and the IP Address of the GSM gateway:

Numbers from 40000000 to 40005000 will be routed to the GSM gateway 10.9.5.45


Note icon It must be the same number of digits in the Number Start and the Number Stop field.



In the Edge Controller, Server Configuration > Direct Access Keys, define in "Ringlist 1" the phone numbers to call. Add the expression ";pause=5" after each number to insert a pause of 5 seconds between each call. This pause is mandatory.

Fill in the Ringlist, then configure the call button to use that Ringlist


If there is a need for more than one sequence, then use "Ringlist 2" and "Ringlist 3", and configure stations to call to that ringlist instead.

The default ringing time is 60 seconds before it goes to the next in the sequence. If you need to change this time, you have to log on to the calling station it self:

  1. Log on to the calling station (not the Edge Controller)
  2. Enable Advanced Configuration Mode
  3. Go to Edge Configuration > Direct Access Keys. Scroll down to the bottom of the page, and set Ringing Time to the interval you want.
  4. As an option, one can have individual ringing time on each entry by adding ";ringing_time=xx" after the entry, e.g.:
:: 40002547;pause=5;ringing_time=40
::40002587;pause=5;ringing_time=30
::40002556;pause=5;ringing_time=55
::40002549



Call button (DAK 1) will call three different phone numbers in sequence at 25 seconds interval


In the GSM Gateway, configure outgoing calls to use "enbloc" (one-stage) dialing. Go to Route > Lan To Mobile Settings.

On item 0, enter:

  • URL = *
  • Call Num = #
Outgoing calls using Enbloc dialing





Software Upgrade

To do a software upgrade, go to Update > New Firmware:

  1. Select the firmware code type "Risc".
  2. Click the Browse button and navigate to the file you want to download
  3. Click the Submit button
Software upgrade



After a software upgrade you must load default settings by selecting Update > Default Settings > Default.