GUI does not react as expected in VS-Operator

From Zenitel Wiki

Revision as of 10:49, 24 October 2023 by Roarl (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
AI.png

Sometimes it appears that the GUI does not react when there is a call or call request to the associated intercom in the VS-Operator client. The call or call request may not appear or VS-Operator does not send commands to ICX-AlphaCom when clicking an icon. The following message will be displayed in the Journal if this is a visible element on the screen: Operator station is not defined correctly, please contact the system administrator.

The VS-Operator client operationally associates the intercom directory number at client start up. Therefore, when using the options dialog to make the association there will be a message that the VS-Operator client needs to be restarted. But the association only works if the intercom has already been defined in VS-Operator.

It may happen that you already know which intercom to associate with the client, even before it is defined in VS-Operator and that you already make the settings in the options dialog. But, when then later the intercom is defined in VS-Operator, the client must be stopped and restarted again for the association to take effect.

So in short:

  • Make certain that the station which is defined as operator is known to VS-Operator as an intercom device
  • Restart the VS-Operator client to apply the association