Actions

Difference between revisions of "Heavy Duty Industrial Master Station - 1007086000"

From Zenitel Wiki

(Connections)
 
(22 intermediate revisions by 3 users not shown)
Line 1: Line 1:
[[image:Heavy Duty Industrial Master Station 100 7086 000.jpg|thumb|100px|]]
+
{{A}}
 +
[[Image:1007086000.PNG|thumb|250px|Industrial Master Station]]
  
== Features ==
+
The '''Heavy Duty Industrial Master Station''' is an analog intercom station. It is connected to an [[ASLT|ASLT line card]] in an [[AlphaCom XE7]], [[AlphaCom XE20]] or [[AlphaCom XE26]] server using 2 pairs of wires.
 +
 
 +
==Highlights==
 
* Master station with free access to all extensions and features
 
* Master station with free access to all extensions and features
* Rugged waterproof and dustproof casing of orange silumin (aluminium alloy)
+
* Rugged waterproof and dustproof casing of orange aluminium alloy
 
* Microphone along with red microphone live lamp
 
* Microphone along with red microphone live lamp
 
* External loudspeaker. Sound level adjustable with a potentiometer inside the station
 
* External loudspeaker. Sound level adjustable with a potentiometer inside the station
 
* Built-in 10 W (8 ohm) VOX operated power amplifier for external loudspeaker
 
* Built-in 10 W (8 ohm) VOX operated power amplifier for external loudspeaker
 
* Screw terminals for easy connection of installation cables
 
* Screw terminals for easy connection of installation cables
* Freely programmable extension number (up to 8 digits as from AMC software version 9.0)
 
 
* Equipped with 4 direct access keys
 
* Equipped with 4 direct access keys
 +
<br>
 +
 +
== Connections ==
 +
[[image:708x Connections.png|thumb|left|500px|]]
 +
<br style="clear:both;" />
 +
 +
For details on connection at the AlphaCom server side, see [[ASLT - AlphaCom Subscriber Line Board]]
 +
 +
<br>
 +
 +
=== Private/Open setting ===
 +
The jumper S1 determines if the station is in private or open mode.
 +
* S1 in upper position: Open mode
 +
* S1 in lower position: Private mode
 +
<br>
 +
 +
=== External loudspeaker  ===
 +
'''External loudspeaker - Powered from the exchange:'''
 +
* Connect an external 20 ohm loudspeaker to the '''L.SP.''' output
 +
* Set the jumpers S5 and S9 in the lower position
 +
* Adjust volume with RP2
 +
 +
'''External loudspeaker - Using the built-in 10 watt amplifier:'''
 +
* Connect an external 8 ohm loudspeaker to the '''L.SP.''' output
 +
* Set the jumpers S5 and S9 in the upper position
 +
* Connect a 12VAC transformer as indicated in the above drawing
 +
* Adjust volume with RP5
 +
<br>
 +
 +
=== Handset connection ===
 +
When handset is connected, open shunt S8 and S11. <br>
 +
[[File:7080_handset_conn.PNG|thumb|left|500px]]
 +
<br style="clear:both;" />
  
== Description ==
+
==== Handset troubleshooting ====
This Industrial Master station is a waterproof model designed for humid, dirty and outdoor conditions. The
+
*'''Symptom:''' When an industrial station type 100 7080 000 is equipped with a handset there is a knows issue related to the handset operation: when the handset is replaced (on-hook) during conversation, the conversation does not cancel.
unit can operate in an ambient temperature range from
+
*'''Solution:''' A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V. <br>
-20o to +50oC (-4oF to +122oF). The station consists of a
+
[[File:7080_handset_cancel.PNG|thumb|left|500px]]
rugged waterproof and dustproof casing (Ip65) of orange
+
<br style="clear:both;" />
silumin. The front panel is hinged to the back casing to
+
<br>
allow easy access during installation and service. The
 
station has screw terminals with labels and the 4 glands
 
allow waterproof and dustproof connection of installation
 
cable and loudspeaker wires.
 
  
The station is equipped with an internal electret
+
== Dimensional Drawing ==
microphone. The volume is adjustable with a
+
[[File:7086Dimensions1.PNG|600px]]
potentiometer located inside the casing. An external 20-
+
<br style="clear:both;" />
70 ohm speaker can be connected or, alternatively,
+
[[File:7086Dimensions2.PNG|300px]]
connect an 8-20 ohm speaker for use with the built-in 10
+
<br style="clear:both;" />
W (8 ohm) VOX operated power amplifier. The power
 
amplifier requires a separate 12 V AC/2 A power supply.
 
The external speaker must be placed at least one meter
 
away from the station.
 
  
The station is programmable for permanent private mode
+
== Related articles ==
and is also prepared for connection of an external
+
* [http://www.zenitel.com/product/industrial-master-station Additional Documentation on Zenitel.com]
handset unit.
 
  
== Installation ==
+
[[Category: Analogue 4-wire Stations]]
[[image:Heavy Duty Industrial Master Station 100 7086 000 Installation.jpg|left|thumb|250px|]]
 

Latest revision as of 12:46, 31 August 2018

AlphaCom icon 300px.png
Industrial Master Station

The Heavy Duty Industrial Master Station is an analog intercom station. It is connected to an ASLT line card in an AlphaCom XE7, AlphaCom XE20 or AlphaCom XE26 server using 2 pairs of wires.

Highlights

  • Master station with free access to all extensions and features
  • Rugged waterproof and dustproof casing of orange aluminium alloy
  • Microphone along with red microphone live lamp
  • External loudspeaker. Sound level adjustable with a potentiometer inside the station
  • Built-in 10 W (8 ohm) VOX operated power amplifier for external loudspeaker
  • Screw terminals for easy connection of installation cables
  • Equipped with 4 direct access keys


Connections

708x Connections.png


For details on connection at the AlphaCom server side, see ASLT - AlphaCom Subscriber Line Board


Private/Open setting

The jumper S1 determines if the station is in private or open mode.

  • S1 in upper position: Open mode
  • S1 in lower position: Private mode


External loudspeaker

External loudspeaker - Powered from the exchange:

  • Connect an external 20 ohm loudspeaker to the L.SP. output
  • Set the jumpers S5 and S9 in the lower position
  • Adjust volume with RP2

External loudspeaker - Using the built-in 10 watt amplifier:

  • Connect an external 8 ohm loudspeaker to the L.SP. output
  • Set the jumpers S5 and S9 in the upper position
  • Connect a 12VAC transformer as indicated in the above drawing
  • Adjust volume with RP5


Handset connection

When handset is connected, open shunt S8 and S11.

7080 handset conn.PNG


Handset troubleshooting

  • Symptom: When an industrial station type 100 7080 000 is equipped with a handset there is a knows issue related to the handset operation: when the handset is replaced (on-hook) during conversation, the conversation does not cancel.
  • Solution: A component must be changed on the station PCB; A100C01433, in order to make the converstion cancel. Change capacitor C14 (47µF/100V) to 4,7µF/63V.
7080 handset cancel.PNG



Dimensional Drawing

7086Dimensions1.PNG
7086Dimensions2.PNG

Related articles