Actions

IF/ENDIF

From Zenitel Wiki

Revision as of 10:07, 11 January 2017 by Mlenes (talk)
AlphaCom icon 300px.png

The IF and ENDIF statements are used in the Event Handler. If the expression following the IF evaluates to the number zero, the following statements are skipped until a (matching) ENDIF is found. The IF statement can test numeric values only.

The IF - ENDIF statements can be nested.

The statement STOP stops the execution of the action string.

Example:

IF %udd(1)
  LOG “Variable 1 is true”
  STOP
ENDIF
LOG “Variable 1 is false”