Actions

Difference between revisions of "INCA Substation LED Indicators"

From Zenitel Wiki

(8022 - IP Substation)
(Station LED)
 
(6 intermediate revisions by the same user not shown)
Line 1: Line 1:
==8022 - IP Substation==
+
===Station LED===
 +
{|
 +
|[[File:IP Substation Indication 1.PNG|thumb|200px|IP Substation LED]]
 +
|[[File:IP Substation Indication 2.PNG|thumb|200px|IP Substation (3gang) LED]]
 +
|}
  
 
===Indications===
 
====Station LED (on board and front plate)====
 
[[File:IP Substation Indication 1.PNG|left|thumb|200px|Station LED]]
 
<br style="clear:both;" />
 
[[File:IP Substation Indication 2.PNG|left|thumb|200px|Station LED]]
 
 
<br style="clear:both;" />
 
<br style="clear:both;" />
<u>'''Blinking at 1 second intervals:'''</u>
+
'''Blinking at 1 second intervals:'''<br>
*Station has no connection to the AlphaCom XE Audio Server.
+
Station cannot register to the server/controller
  
 
Possible reasons:
 
Possible reasons:
:*No connection to Ethernet
+
* Invalid network settings (IP address and network mask) in the device
:*Wrong AlphaCom IP address configured
+
* Wrong or missing account settings (Server IP, directory number, password..)
:*Invalid IP address
+
* Failing to register due to missing license in the server
:*No gateway or wrong gateway to the AlphaCom XE Audio Server
+
* The server is offline
 +
* Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)
 +
If the server is on a different subnet, check that
 +
* A valid Default gateway is defined
  
<u>'''Blinking at 5 second intervals:'''</u>
+
'''No blinking:'''
*Station connected but NOT registered in the AlphaCom XE Audio Server.
 
  
Reason:  
+
Possible reasons:  
:*Station has not been programmed in AlphaPro
+
* Station connected and registered to the server/controller
:*Missing IP Station license in AlphaCom XE Audio Server
+
* Station not powered up (if no other LEDs are active)
  
<u>'''No blinking:'''</u>
+
'''Blinking at 5 second intervals:'''<br/>
 +
{{Note| This LED behaviour only applies in ICX-AlphaCom mode}}
 +
Station connected but NOT registered in the ICX-AlphaCom
  
 
Possible reasons:  
 
Possible reasons:  
:*Station connected and registered to the AlphaCom XE Audio Server
+
* Station has not been programmed in AlphaPro
:*Station not powered up (if no other LEDs are active)
+
* Missing IP Station license in ICX-AlphaCom
 
 
====Status LED====
 
Bicolor SMD LED on board component side.
 
[[File:IP Substation Indication 3.PNG|left|thumb|200px|Status LED]]
 
<br style="clear:both;" />
 
<u>'''Blinking 2 red + 1 green:'''</u>
 
:*Station has no connection to the AlphaCom XE Audio Server.
 
<u>'''Blinking 1 red + 2 green:'''</u>
 
:*Station connected but NOT registered in the AlphaCom XE Audio Server.
 
<u>'''Blinking 3 green:'''</u>
 
:*Station connected and registered in the AlphaCom XE Audio Server.
 
 
 
====LAN LEDs====
 
<u>'''Left LED:'''</u>
 
[[File:IP Substation Indication 4.PNG|left|thumb|200px|Left LED]]
 
<br style="clear:both;" />
 
*Steady light:  Ethernet connection OK
 
*Blinking:    Ethernet traffic
 
*No light:    No Ethernet connection
 
  
<u>'''Right LED:'''</u>
+
[[Category:Station Indication LEDs]]
[[File:IP Substation Indication 5.PNG|left|thumb|200px|Right LED]]
 
<br style="clear:both;" />
 
*Light:    100 Mbit Ethernet connection
 
*No light:  10 Mbit Ethernet connection
 

Latest revision as of 12:44, 20 November 2020

Station LED

IP Substation LED
IP Substation (3gang) LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the server/controller
  • Station not powered up (if no other LEDs are active)

Blinking at 5 second intervals:

Note icon This LED behaviour only applies in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom