Actions

INCA Substation LED Indicators

From Zenitel Wiki

Revision as of 09:17, 20 November 2020 by Roarl (talk | contribs)

Station LED

IP Substation LED
IP Substation (3gang) LED


Blinking at 1 second intervals:
Station has no connection to the ICX-AlphaCom Server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the ICX-AlphaCom Server

Blinking at 5 second intervals:
Station connected but NOT registered in the ICX-AlphaCom Server.

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in ICX-AlphaCom Server

No blinking:

Possible reasons:

  • Station connected and registered to the ICX-AlphaCom Server
  • Station not powered up (if no other LEDs are active)