Actions

Difference between revisions of "IND - Indicator control for CRMIV LEDs, buzzer etc."

From Zenitel Wiki

(Syntax)
(Syntax)
Line 5: Line 5:
  
 
'''phys.no''':
 
'''phys.no''':
*1-552 = The physical number of the station<br>
+
:*1-552 = The physical number of the station
 
 
  
 
'''key.no''':  
 
'''key.no''':  
*1-100 = The key number of the DAK-key <br>
+
:*1-100 = The key number of the DAK-key <br>
*1023 = Buzzer
+
:*1023 = Buzzer
*1024 = Display
+
:*1024 = Display
  
 
'''led.no/buzzer''': <br>
 
'''led.no/buzzer''': <br>
If the previous parameter was DAK-key (1 - 100):
+
:If the previous parameter was DAK-key (1 - 100):
*1 = Red LED
+
:*1 = Red LED
*2 = Green LED
+
:*2 = Green LED
 +
 
 +
:If the previous parameter was Buzzer (1023):
 +
:*1 = Internal buzzer
 +
:*2 = External buzzer (relay)
  
If the previous parameter was Buzzer (1023):  
+
:If the previous parameter was Display (1024):
*1 = Internal buzzer
+
:*1 = Backlight
*2 = External buzzer (relay)
 
  
If the previous parameter was Display (1024):
+
'''ind-type''':
*1 = Backlight
+
:LEDs and display:
 +
1 = continuous (low priority)
 +
2 = slow flash (medium priority)  
 +
3 = fast flash (high priority)
  
'''ind-type''': LEDs and display: Buzzers
+
:Buzzers:
1 = continuous (low priority) 1 = 1 bleep per 8 seconds (low priority)
+
:*1 = 1 bleep per 8 seconds (low priority)
2 = slow flash (medium priority) 2 = 1 bleep per 2 seconds (medium priority)
+
:*2 = 1 bleep per 2 seconds (medium priority)
3 = fast flash (high priority) 3 = 4 bleeps per second (high priority)
+
:*3 = 4 bleeps per second (high priority)
4 = continuous (alarm priority)
+
:*4 = continuous (alarm priority)
See “multiple LED functions” below.
 
  
  

Revision as of 22:36, 10 November 2007

Syntax

IND  <phys.no>  <key.no>  <led.no/buzzer>  <ind-type>  [ON/OFF]


phys.no:

  • 1-552 = The physical number of the station

key.no:

  • 1-100 = The key number of the DAK-key
  • 1023 = Buzzer
  • 1024 = Display

led.no/buzzer:

If the previous parameter was DAK-key (1 - 100):
  • 1 = Red LED
  • 2 = Green LED
If the previous parameter was Buzzer (1023):
  • 1 = Internal buzzer
  • 2 = External buzzer (relay)
If the previous parameter was Display (1024):
  • 1 = Backlight

ind-type:

LEDs and display:

1 = continuous (low priority) 2 = slow flash (medium priority) 3 = fast flash (high priority)

Buzzers:
  • 1 = 1 bleep per 8 seconds (low priority)
  • 2 = 1 bleep per 2 seconds (medium priority)
  • 3 = 4 bleeps per second (high priority)
  • 4 = continuous (alarm priority)


[state] OFF or ON (capital letters) The brackets [ ] indicate that this command is optional. If nothing is entered in this field, the indication is switched on/off along with the event. By entering OFF, for example, you can set an indication to turn off when the event turns on.

Example

IND  2  23  2  3  ON – Station 2, key 23, turn green led, fast flashing, ON