Actions

IP Desktop with Video Display - Release Notes

From Zenitel Wiki

Revision as of 10:44, 12 August 2015 by Roarl (talk)

Note: These release notes are for the video part of the unit only.

Contents

Firmware version 1.0

Release

Firmware version 1.1

Error corrected

Network bug

Fixed a network bug in DHCP mode

Enhancements

Network stability

Improved network stability

Firmware version 1.2

Error corrected

LED's not switching off

Fixed a bug where the LEDs weren't correctly switched off when the state changed from "incoming call" to "idle"

Enhancements

Web Interface

Fixed a problem with the web server, that could cause problems, if someone tries to access the web interface, while the device has initiated a reboot


Firmware version 1.3

Error corrected

LED's not updated correctly

Fixed a bug where the LED's weren't correctly updated in some scenarios

Enhancements

None

Firmware version 1.4

Error corrected

None

Enhancements

DIP Protocol

Implemented DIP protocol via internal serial interface

Bootloader

Implemented bootloader with firmware upload via web interface

Firmware version 1.5

Error corrected

None

Enhancements

Encryption

Implemented encryption of the firmware file

Workflowad aptation

Firmware version 1.6

Error corrected

Display don't clear properly

Fixed a bug where the display wasn't cleared correctly in some cases

Enhancements

Font Improvements

Font improvements (narrow characters are now centered instead of left aligned)

Firmware version 1.7

Error corrected

None

Enhancements

DIP messages

Added detection of missing DIP messages

Changed Font

Changed font to a fixed-width font

Increased camera count

Increased camera count to 48

Manual camera selection

Added manual camera selection with passcode authentication via display

Automatic camera switching

Added automatic camera switching, if more than one camera is added to a remote station

GUI overhaul

Overhauled the UI and web interface

Camera list

Added a download/upload functionality for the camera list

Save & Reboot

The station does not need to reboot anymore, after changing the settings

Factory reset

Added factory reset via web interface

Firmware version 1.8

Error corrected

Passcode required

Fixed a bug where, in manual camera selection, the first element in the list always required a passcode, even when passcode authentication was disabled

Authentication in IE9+

Fixed a web server bug that was causing problems with digest authentication under IE9+

Wrong camera connected

Fixed a bug that incorrectly reconnected a camera, when another camera is manually selected during a connected call

Timing issue

Fixed a timing problem when trying to connect to the camera of an incoming call, when manual camera selection is active

Enhancements

Axis camera URL

Changed the URL for Axis cameras from "mjpg/video.mjpg" to "axis-cgi/mjpg/video.cgi"

MJPG stream compatibility

Changed the MJPG stream function to be compatible with older non-RFC-compliant Axis cameras

LED behaviour

Changed the behaviour of the LED (the "auo" DIP message does no longer turn off the LED)

"aue" DIP message

The "aue" DIP message is now ignored

Fallback settings

Changed the fallback settings for username and password to "admin"/"alphaadmin"

LED time base

Changed the LED time base

Streaming wrong format/resolution

The station now displays an error screen when trying to stream a video in the wrong format/resolution


Firmware version 1.9

Error corrected

Display text not cleared properly

Fixed a bug where some display texts weren't cleared correctly

Enhancements

Grundig camera support

Added the MJPG streaming path for Grundig cameras

Firmware version 1.10

Error corrected

None

Enhancements

Grundig camera support

Removed the MJPG streaming path for Grundig cameras

Custom camera support

Added a dnyamic list for up to 3 custom camera types including streaming path

Firmware version 1.11

Error corrected

None

Enhancements

Factory reset

Added factory reset via display

Custom camera type name

Increased the length of the camera type name in the dynamic camera type list to 100 characters

Increased camera count

Increased camera count to 80

Camera name

Increased camera name to 15 characters

Firmware version 1.12

Error corrected

Incorrect IP settings

Fixed a bug when entering an IP address and a subnet mask that don't "fit"

Enhancements

None


Firmware version 1.13

Error corrected

Camera type list

Fixed an index error in the camera type list

Invalid camera URL caused endless loop

Fixed an endless loop when trying to access an invalid camera URL


Enhancements

Resynchronisation timer

The resync timer for the camera stream will now be stopped, when resyncronisation is successful