{|border="1"
|width="150px"|LAN
+
|width="180px"|LAN
 
|10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
 
|10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
 
|-
 
|-
Line 25: Line 25:
 
If PoE is not available, the IP Flush Master Station  can be connected to a 24 VDC local power supply.  
 
If PoE is not available, the IP Flush Master Station  can be connected to a 24 VDC local power supply.  
  
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
+
See Related Articles [[IP Flush Master -V2 Board Connectors]] and [[INCA Master Station Kit Board Connectors]] for local power supply connections.
  
 
== Network Connection ==
 
== Network Connection ==
Line 42: Line 42:
 
:* 1 relay output (P3)
 
:* 1 relay output (P3)
 
<br/>
 
<br/>
These connections are used as relay contacts for door lock control and external I/O devices.
+
These connections are used as relay contacts for door lock control and external I/O devices. <br>
For pin settings on the P3 and P4 connectors on the station board, see [[INCA Master Station Kit Board Connectors]].
+
For pin settings on the P3 and P4 connectors on the station board, see [[INCA Master Station Kit Board Connectors]] or [[IP Flush Master Station Kit Board Connectors]].
  
  
  
 
[[Category: INCA Connections]]
 
[[Category: INCA Connections]]
 +
[[Category: Turbine Connections]]

Revision as of 09:22, 11 October 2021

Introduction

The table below is an overview of the main connectors involved when installing the IP Flush Master Stations.

LAN 10/100 Mbps RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
AUX 10/100 Mbps RJ-45 ports for auxiliary equipment such as PC and IP camera.
Handset Port RJ11
Headset Port RJ11
Input/Output Pluggable screw terminal
Extension Unit (IP DAK-48) RJ45
Local Power Plugable screw terminal, 19-27 VDC Idle 4W, max. 8W

Power Supply

The IP Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.

If PoE is not available, the IP Flush Master Station can be connected to a 24 VDC local power supply.

See Related Articles IP Flush Master -V2 Board Connectors and INCA Master Station Kit Board Connectors for local power supply connections.

Network Connection

There are two RJ45 ports on the IP Stations:

  • LAN port: for connecting to the network and the AlphaCom XE Audio Server.
  • AUX port: for connecting to auxiliary equipment such as a PC or IP Camera.
IP Flush Master, IP OR, IP Master Kit - Rear view

Input/Output Connections

There are I/O connection options for all IP Stations, except the IP Desktop Station and the IP Dual Display Station. These I/O connections include:

  • 3 digital inputs (P4)
  • 1 logical output (TP9)
  • 1 relay output (P3)


These connections are used as relay contacts for door lock control and external I/O devices.
For pin settings on the P3 and P4 connectors on the station board, see INCA Master Station Kit Board Connectors or IP Flush Master Station Kit Board Connectors.