Difference between revisions of "IP Flush Master Station LED Indications"
From Zenitel Wiki
Line 1: | Line 1: | ||
== Station LED == | == Station LED == | ||
− | |||
[[File:IP Master Indications 1.PNG|left|thumb|200px|Station LED]] | [[File:IP Master Indications 1.PNG|left|thumb|200px|Station LED]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> |
Revision as of 11:41, 26 October 2016
Contents
Station LED
Blinking at 1 second intervals:
Station has no connection to the AlphaCom XE Audio Server.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom IP address configured
- Invalid IP address
- No gateway or wrong gateway to the AlphaCom XE Audio Server
Blinking at 5 second intervals:
Station connected but NOT registered in the AlphaCom XE Audio Server.
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in AlphaCom XE Audio Server
No blinking:
Possible reasons:
- Station connected and registered to the AlphaCom XE Audio Server
- Station not powered up (if no other LEDs are active)
Status LED
LED3 – Bicolor SMD LED on board component side.
Blinking 2 red + 1 green:
- Station has no connection to the AlphaCom XE Audio Server.
Blinking 1 red + 2 green:
- Station connected but NOT registered in the AlphaCom XE Audio Server.
Blinking 3 green:
- Station connected and registered in the AlphaCom XE Audio Server.
Power LED
LED6 – Yellow SMD LED on board component side.
- Light: 13VDC board power OK.
- No light: 13VDC board power faulty if no other LEDs are lit.
Possible reasons:
- 24 VDC or PoE not connected
- Faulty board
LAN LEDs
Left LED:
- Steady light: Ethernet connection OK
- Blinking: Ethernet traffic
- No light: No Ethernet connection
Right LED:
- Light: 100 Mbit Ethernet connection
- No light: 10 Mbit Ethernet connection