Actions

Difference between revisions of "IP Flush Master Station LED Indications"

From Zenitel Wiki

Line 23: Line 23:
 
* Station connected and registered to the AlphaCom XE Audio Server
 
* Station connected and registered to the AlphaCom XE Audio Server
 
* Station not powered up (if no other LEDs are active)
 
* Station not powered up (if no other LEDs are active)
 
== Status LED ==
 
LED3 – Bicolor SMD LED on board component side.
 
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]]
 
<br style="clear:both;" />
 
'''Blinking 2 red + 1 green:'''<br>
 
* Station has no connection to the AlphaCom XE Audio Server.
 
 
'''Blinking 1 red + 2 green:'''<br>
 
* Station connected but NOT registered in the AlphaCom XE Audio Server.
 
 
'''Blinking 3 green:'''
 
* Station connected and registered in the AlphaCom XE Audio Server.
 
 
== Power LED ==
 
LED6 – Yellow SMD LED on board component side.
 
[[File:MasterStationKit Indications2.png|left|thumb|400px|Power LED]]
 
<br style="clear:both;" />
 
* Light:  13VDC board power OK.
 
* No light:  13VDC board power faulty if no other LEDs are lit.
 
 
Possible reasons:
 
* 24 VDC or PoE not connected
 
* Faulty board
 
 
== LAN LEDs ==
 
'''Left LED:'''<br>
 
[[File:IP Master Indications 4.PNG|left|thumb|200px|Left LED]]
 
<br style="clear:both;" />
 
* Steady light:  Ethernet connection OK
 
* Blinking:    Ethernet traffic
 
* No light:    No Ethernet connection
 
 
'''Right LED:'''<br>
 
[[File:IP Master Indications 5.PNG|left|thumb|200px|Right LED]]
 
<br style="clear:both;" />
 
* Light:    100 Mbit Ethernet connection
 
* No light:  10 Mbit Ethernet connection
 
  
 
[[Category:INCA Indication LEDs]]
 
[[Category:INCA Indication LEDs]]

Revision as of 11:54, 26 October 2016

Station LED

Station LED


Blinking at 1 second intervals:
Station has no connection to the AlphaCom XE Audio Server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom XE Audio Server

Blinking at 5 second intervals:
Station connected but NOT registered in the AlphaCom XE Audio Server.

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in AlphaCom XE Audio Server

No blinking:

Possible reasons:

  • Station connected and registered to the AlphaCom XE Audio Server
  • Station not powered up (if no other LEDs are active)