==Status LED==
+
== Station LED ==
 +
LED4 - Red 5mm LED on board rear side, also seen through front plate.
 +
[[File:IP Master Indications 1.PNG|left|thumb|200px|Station LED]]
 +
<br style="clear:both;" />
 +
'''Blinking at 1 second intervals:'''<br/>
 +
Station has no connection to the AlphaCom XE Audio Server.
 +
 
 +
Possible reasons:
 +
* No connection to Ethernet
 +
* Wrong AlphaCom IP address configured
 +
* Invalid IP address
 +
* No gateway or wrong gateway to the AlphaCom XE Audio Server
 +
 
 +
'''Blinking at 5 second intervals:'''<br/>
 +
Station connected but NOT registered in the AlphaCom XE Audio Server.
 +
 
 +
Possible reasons:
 +
* Station has not been programmed in AlphaPro
 +
* Missing IP Station license in AlphaCom XE Audio Server
 +
 
 +
'''No blinking:'''
 +
 
 +
Possible reasons:
 +
* Station connected and registered to the AlphaCom XE Audio Server
 +
* Station not powered up (if no other LEDs are active)
 +
 
 +
== Status LED ==
 
LED3 – Bicolor SMD LED on board component side.
 
LED3 – Bicolor SMD LED on board component side.
 
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]]
 
[[File:MasterStationKit Indications1.png|left|thumb|400px|Status LED]]
Line 12: Line 38:
 
* Station connected and registered in the AlphaCom XE Audio Server.
 
* Station connected and registered in the AlphaCom XE Audio Server.
  
==Power LED==
+
== Power LED ==
 
LED6 – Yellow SMD LED on board component side.
 
LED6 – Yellow SMD LED on board component side.
 
[[File:MasterStationKit Indications2.png|left|thumb|400px|Power LED]]
 
[[File:MasterStationKit Indications2.png|left|thumb|400px|Power LED]]
Line 23: Line 49:
 
* Faulty board
 
* Faulty board
  
==LAN LEDs==
+
== LAN LEDs ==
 
'''Left LED:'''<br>
 
'''Left LED:'''<br>
 
[[File:IP Master Indications 4.PNG|left|thumb|200px|Left LED]]
 
[[File:IP Master Indications 4.PNG|left|thumb|200px|Left LED]]

Revision as of 12:39, 25 October 2016

Station LED

LED4 - Red 5mm LED on board rear side, also seen through front plate.

Station LED


Blinking at 1 second intervals:
Station has no connection to the AlphaCom XE Audio Server.

Possible reasons:

  • No connection to Ethernet
  • Wrong AlphaCom IP address configured
  • Invalid IP address
  • No gateway or wrong gateway to the AlphaCom XE Audio Server

Blinking at 5 second intervals:
Station connected but NOT registered in the AlphaCom XE Audio Server.

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in AlphaCom XE Audio Server

No blinking:

Possible reasons:

  • Station connected and registered to the AlphaCom XE Audio Server
  • Station not powered up (if no other LEDs are active)

Status LED

LED3 – Bicolor SMD LED on board component side.

Status LED


Blinking 2 red + 1 green:

  • Station has no connection to the AlphaCom XE Audio Server.

Blinking 1 red + 2 green:

  • Station connected but NOT registered in the AlphaCom XE Audio Server.

Blinking 3 green:

  • Station connected and registered in the AlphaCom XE Audio Server.

Power LED

LED6 – Yellow SMD LED on board component side.

Power LED


  • Light: 13VDC board power OK.
  • No light: 13VDC board power faulty if no other LEDs are lit.

Possible reasons:

  • 24 VDC or PoE not connected
  • Faulty board

LAN LEDs

Left LED:

Left LED


  • Steady light: Ethernet connection OK
  • Blinking: Ethernet traffic
  • No light: No Ethernet connection

Right LED:

Right LED


  • Light: 100 Mbit Ethernet connection